Installation - ADTRAN T200 H2TU-R Installation And Maintenance Manual

Circuit pack 2-wire hdsl hdsl2 remote unit
Hide thumbs Also See for T200 H2TU-R:
Table of Contents

Advertisement

This version of the H2TU-R works with multiple list
versions of the HDSL2 transceiver unit for the central
office (H2TU-C) as listed below.
Unit Number
1221001LX .............. 220/E220 H2TU-C
1221002L1 ............... LiteSpan
1221003LX .............. DDM+ H2TU-C
1221004LX .............. 3192 H2TU-C
1221006L6 ............... T200 H2TU-C
1221007L4 ............... H2TU-C for Soneplex
1181111LX .............. Total Access
1222001LX .............. 2
1222003LX .............. 2
1222004LX .............. 2
1222007L4 ............... 2
1181112LX .............. 2
The H2TU-R can be deployed in circuits using one
H2TU-C and one H2TU-R.
The H2TU-R terminates local loop HDSL2 signals
originating from the Central Office (CO) unit and
transforms the HDSL2 signal into traditional DS1
signals to be delivered to the customer.
The H2TU-R (P/N 1222026L7) can be used with any
H2TU-C to complete a fully span-powered HDSL2
circuit. Span power is provided from the H2TU-C. Span
powering meets all requirements of Class A2 voltages as
specified by Bellcore GR-1089-CORE. This unit is
intended for Span Power Only. If a locally power unit
is needed, refer to P/N 1222024L7.
Revision History
This is the second release of this document. This
revision includes update Provisioning and Alarm
History Screen.
2
Description
®
H2TU-C
®
LEC
®
H2TU-C
nd
Gen 220/E220 H2TU-C
nd
Gen DDM+ H2TU-C
nd
Gen 3192 H2TU-C
nd
®
H2TU-C for Soneplex
nd
Gen Total Access H2TU-C
Section 61222026L7-5, Issue 2

2. INSTALLATION

C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
After unpacking the unit, inspect it for damage. If
damage is discovered, file a claim with the carrier,
then contact ADTRAN. See Warranty and Customer
Service.
The settings on the H2TU-C are encoded and
transmitted to the H2TU-R once the circuit has
achieved synchronization. There are no switch
settings on the H2TU-R.
Remote Provisioning
This H2TU-R can be used to provision the entire
HDSL2 circuit via the craft interface.
Compliance Codes
Table 1 shows the Compliance Codes for the
H2TU-R. The H2TU-R complies with the requirements
covered under UL 60950 third edition and is intended
to be installed in an enclosure with an Installation
Code (IC) of "B" or "E."
Table 1. Compliance Codes
Code
Installation Code (IC)
Telecommunication Code (TC)
Power Code (PC)
NOTE
This product is intended for installation in
RESTRICTED ACCESS LOCATIONS only.
Up to -200 Vdc may be present on the HDSL2
telecommunications port.
Front Panel Indicators
There are nine front panel mounted status indicators.
Each indicator is described in Table 2.
Front Panel DS1 Monitor Jack
The H2TU-R provides DS1 monitor bantam jacks.
These jacks provide a test point for DS1 traffic to and
from the customer. See Section 4, HDSL2, System
Testing, for more details.
Input
Output
A
X
X
C
C
61222026L7-5B