Philips FM92E Manual page 73

Conversion to 6 meters
Table of Contents

Advertisement

receive multiple and variable selcalls (used for sending status, etc)
G – Selcall Options
Note that most selcall hybrids can only respond to CCIR selcall tones,
the other selcall modes were not well supported.
H – Other Options
Software Code
made up of 15 Digits:
The software code for a FM92E with remote head for 6 Meters = 110404200000000
A – Channel Display
B – Mute
C – Economiser Options
D – Tx Timer
E – Tx Inhibit
F – Tx power
G – Scanning
H – Voting
Philips FM92E Conversion to 6 Meters:
0 =
none
1 = CCIR
2 = ZVE 1 selcall
3 = EEA
4 = EIA
5 = No
6 = CCIR
7 = ZVE
8 = EEA
9 = EIA
0 = standard version
1 = reverse tone burst
2 = dual front end
3 = ignition noise blanker
0 = intermittent display
1 = continuous display
2 = intermittent + 8 hour timer (auto power off)
3 = continuous display + 8 hour timer
0 = fixed, with defeat
1 = variable with defeat
2 = fixed, no defeat
3 = variable, no defeat
0 = Off
1 =
1 minute
2 =
3 minutes
3 =
5 minutes
4 = 10 minutes
0 = Off
1 = Tx inhibit all channels
0 = 25 watts
1 =
5 watts
2 =
1 watt
3 =
Operator selectable
4 =
per channel option
6 =
5-25 watts
7 =
1-25 watts adjustable
0 = none
1 = scan vacant per programmed blocks
2 = scan occupied per programmed blocks
3 = scan occupied, operator selectable, per programmed blocks
0 = No voting
selcall
selcall
selcall
selcall
with I/O expansion kit
selcall, encode type 2
selcall, encode type 2
selcall, encode type 2
selcall, encode type 2
Version 3.9
Page 73