Conversion to 6 meters
Table of Contents

Advertisement

Coil Upgrade:
Remove by de-soldering and upgrade the following coils to the new turns, with the same diameter on the PA
board.
Coil Original Turns
L101
2.5
L103
2.5
L104
2.5
L105
0.75
L106
No change
L107
No change
L108
8.5
L109
2.5
L110
1.0
L111
No change
L112
No change
L113
No change
L114
L115
1.0
L116
2.5
L117
No change
L118
L119
5.5
L120
4.5
L121
5.5
L122
Philips FM92E Conversion to 6 Meters:
New Turns
Wire Size
3.5
0.63mm
3.5
0.63mm
3.5
0.63mm
1.0
0.63mm
10.5
0.80mm
3.5
0.80mm
1.5
0.80mm
2.5
0.80mm
1.5
0.80mm
3.5
0.80mm
6.5
0.80mm
6.5
0.80mm
5.5
0.80mm
5.5
0.80mm
5.0
0.63mm
Drill Size for winding coil
Version 3.9