4.5) Return to original factory settings / fi rmware version
Select screen 10 from the "main menu" (Ref. to § 4.1), to return the pump to its factory setting hold
the finger on the button (4) until a confirmation "beep" is heard.
RESET
The RESET screen also shows the fi rmware version of the control board.
SW: S1J56100
4.6) Errors/Malfunctions
These appear on the display during operation, combined with a beep to notify the operator of
procedural or operational errors. They are accompanied by an audible signal and the Cembre
logo (8) lighting up yellow.
Message
In CRIMPING mode, a 100 bar pres-
sure has been reached or exceeded
ERROR
but the oil discharge has been acti-
vated before waiting for the motor
to be automatically switched off .
The pump has been started with-
out the fl exible hose connected or
the fl e-xible hose is not correctly
connected.
Interruption of the signal from the
NTC
NTC temperature probe of the
FAULT
battery.
Abnormal power consumption of
the motor.
001
The pump stops.
Output voltage of the pressure trans-
002
mitter is out of the pre-set range.
The pump stops and doesn't re-start.
Failure to reach the set pressure
003
within 120 sec. of continuous opera-
tion of the pump.
Overcharging of the battery with
protection tripping.
004
The pump stops.
Errors 00.. are displayed for about 30 seconds before being reset, but will display repeat-
edly in the event of permanent anomalies.
Error description
S
olution
Repeat the work cycle, keeping the start but-
ton pressed down until the motor switches off
automatically.
Press the release button, connect the fl exible
hose or check the correct connection to the
pump.
Replace the battery. If the problem persists,
please contact Cembre.
Wait for the display to turn off (60 sec.) or remove
and re-insert the battery, then re-start the
pump, if the problem persists, please contact
Cembre.
Remove and re-insert the battery, if the prob-
lem persists, please contact Cembre.
Repeat the work cycle; if the problem persists,
please contact Cembre.
Wait for the display to turn off (60 sec.) or re-
move and re-insert the battery, then re-start the
pump. if the problem persists, please contact
Cembre.