4.7 Chimney and fl ue pipe
The fi replace must only be connected to a chimney and
fl ue pipe approved for solid fuel fi replaces with fl ue gas
temperatures as specifi ed in «2.0 Technical Data».
The specifi ed distance to fl ammable materials, applies to
this stove.
The stove must be installed with a CE approved fl ue.
The distance of the fl ue pipe to combustible materials must
also be observed.
The cross-section of the chimney must be designed to fi t
the fi replace. Use «2.0 Technical Data» to calculate the
correct chimney cross-section.
The chimney must be connected in accordance with the
installation instructions of the chimney supplier.
Before a hole is made in the chimney, the product should
be test-mounted in order to correctly mark the position of
the fi replace and the hole in the chimney. See fi g. 1 for
minimum dimensions.
With a rear outlet, use a fl ue pipe bend with a sweep hatch
to allow sweeping.
Please note that it is extremely important for connections
to have a degree of fl exibility. This is to prevent any
movement in the installation leading to the formation of
cracks.
For recommended chimney draught, and fl ue pipe
dimension see "2.0 Technical Data". NB: The chimney's
diameter must be at least just as big as the fl ue pipe.
12
4.5 When using heat-accumulating
stones (optional extra)
Fig. 15
1. Fit the gasket (B) on the end of the fl ue pipe (A).
Fig. 16
2. Push the fl ue pipe (A) down into the top outlet.
A