Features And Benefits - Trane RT-PRC010-EN Manual

Intellipak rooftops 20 - 130 tons — 60 hz
Table of Contents

Advertisement

Standard Features
• 20 to 130 ton industrial/ commercial
rooftops
• Fully integrated, factory-installed/
commissioned microelectronic
controls
• Unit mounted Human Interface Panel
with a 2 line x 40 character English
display and a 16 function key-pad that
includes Custom, Diagnostics, and
Service Test mode menu keys.
®
• Trane 3-D
Scroll compressors
(20 to 130 Tons)
• Compressor or circuit lead/lag
depending on unit
• Horizontal discharge/return duct
connections (SX, SL, SS models)
• CV or VAV control
• Low ambient compressor lockout
control on units with economizers
• FROSTAT™ coil frost protection on
all units
• Daytime Warm-up (Occupied mode)
on VAV models and Morning Warm-up
operation on all units with heating
options
• Supply air static overpressurization
protection on units with inlet guide
vanes and VFD's.
• Supply airflow proofing
• Exhaust airflow proofing on units with
exhaust option
• Supply air tempering control
• Supply air heating control on VAV
modulating hot water or steam heat
units
• Emergency stop input
• Liquid and Discharge Service Valves
• Mappable sensors and setpoint
sources
• Occupied/Unoccupied switching
• Timed override activation
• Forward-curved supply fans
• Pitched roof over air handler section
• Stainless steel flue stack on gas heat
units
• 14-gauge, single-piece construction
base rails
4
Features and
Benefits
• UL and CSA approval on standard
options
• Two-inch spring fan isolation
(90 to 130 tons)
• Meets 672 hours of salt spray testing in
accordance to ASTM B117 Standard
• Two inch standard efficiency
throwaway filters on 20 to 90 ton units
and two inch high efficiency
throwaway filters on 105 to 130 ton
units.
Optional Features
• Trane Communication Interface
Module: ICS interface control module
• Remote Human Interface Panel
(controls up to 4 units)
• Five ventilation override sequences
• Heating options: natural gas, electric,
hot water or steam
• Generic BAS interface
• Choose from three economizer control
options: comparative enthalpy,
reference enthalpy, dry bulb control
• Variable frequency drive control of
supply/exhaust fan motor
• Inlet guide vanes on FC supply fans
(VAV only)
• Outside air CFM compensation on VAV
units with IGV (or VFD) and economizer
• Hot gas bypass to the evaporator inlet
• Copper evaporator/condenser coils
• Suction service valves
• Replaceable core filter driers
• Phenolic coated evaporator/condenser
coils
• High capacity evaporator coils
(20 to 105 tons)
• Special paint colors
• Extended casing (SX models)
• Double wall access doors
• Double wall construction/perforated
double wall
• Stainless steel drain pan in evaporator
section
• Pitch evaporator drain pan
• Filter rack only (no filters)
• High efficiency throwaway filters
• 90-95 percent bag filters
• 90-95 percent cartridge filters
• Final filters
• Barometric relief
• 50 percent modulating exhaust with
forward-curved fans
• Trane's air quality (Traq™) sensor
• Modulating Gas Heat
• 10 year limited warranty on Full
Modulation Gas Heat
• 100 percent modulating exhaust with
forward-curved fans
• 100 percent modulating exhaust with
FC fans and Statitrac™ direct space
sensing building pressurization control
• High duct temperature thermostats
• 0 F low ambient control
• 0-100 percent modulating fresh air
economizer
• Ultra low leak dampers for 0-100
percent modulating fresh air
economizers
• Dual electrical power connection
• Two-inch spring fan isolation
(20 to 75 tons)
• High efficiency motors
• U-frame motors
• Oversized motors
• Thru the door non-fused disconnect
with external handle
• Electrical convenience outlet
• Power supply monitoring
• Correction capacitors
• Horizontal or Roof discharge w/gas
heat (20-75 tons "F" style units only)
Field Installed Accessories
• Roof curbs
• Programmable sensors with night set
back — CV and VAV
• Sensors without night set back — CV
and VAV
• Remote zone sensors — used for
remote sensing with remote panels.
• ICS zone sensors used with Tracer®
system for zone control
• Outdoor temperature sensor for units
without economizers
• Remote minimum position control for
economizer
• Field installed module kits available for
field upgrade of controls
RT -PRC010-EN

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents