Transceiver Length And Sub-Packing Mode; Operating Mode - Ebyte E90-DTU User Manual

Data transceiver
Hide thumbs Also See for E90-DTU:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co,;Ltd

5.6. Transceiver Length and Sub-packing Mode

Model
E90-DTU(433C30)
★ Note:
1. If the data received by the station in a single time is larger than the capacity of a single packet, the excess data
will be automatically allocated to the second transmission until the completion of transmission.
2. The data transceiver cannot receive data which is more than the buffer capacity;

6. Operating Mode

E90-DTU (433C30) has four operating modes, if low power consumption is not required, normal communication is recommended to
configure the data transceiver for the normal mode (mode 0);
The factory default is normal mode (mode 0).
Categories
M ode 0
Normal M ode
M ode 1
Retained mode
M ode 2
Command mode
M ode 3
Sleep M ode
★ Note: no need to care about the wake-up mode (mode 1) and power saving mode (mode 2) if it doesn't request low
power consumption.
Chengdu Ebyte Electronic Technology Co,;Ltd
Copyright ©2012–2019,
Buffer
Single input unlimited (baud
rate ≤57600)
M1
M0
ON
ON
Serial port open, wireless open, transparent transmission (factory default mode)
ON
OFF
OFF
ON
OFF
OFF
The module enters hibernation, and the serial port and module are closed
Sub-package
Continuous transmission, no subcontracting
Description
Nonsense, both serial and wireless are disabled
The radio can be programmed using configuration software