Technical Indicators; Model Specifications - Ebyte E90-DTU User Manual

Data transceiver
Hide thumbs Also See for E90-DTU:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co,;Ltd
4
485_A
★ Note: The transceiver will be in poor co mmunicat ion when connected to multiple devices , it is reco mmended to be
connected to a single device, please try to use parallel 120Ω resistor between 485_A terminal and 485_B.

5. Technical indicators

5.1.

Model specifications

Model
E90-DTU
(230C27)
★ Note: Test condition: in clear and open air without shelters, 12V / 2A power supply, 5d Bi gain sucker antenna over 2
meters height from the ground, with the factory default parameters.
NO.
1
2
3
4
5
6
Communication interface
7
8
Chengdu Ebyte Electronic Technology Co,;Ltd
Copyright ©2012–2019,
RS-485 interface, interface A
Transmit
Frequency
power
Hz
W
230
0.5
Model
Size(H*W*D)
Weight
Temperature
Antenna impedance
Supply voltage
Baud rate
Address
The RS-485 interface A is connected to the device interface A
Distance
Specifications
km
Diffraction
2.8
capability, support
M odbus
Specification
82 * 62 * 25 mm
130g
-40℃~85℃
50 Ω
+10 ~ +28V DC
RS232/RS485
Default 9600
Default 0
E90-DTU (433C30) user manual
Application
Industrial PCL cable to wireless, polling
data acquisition, remote monitoring
Description
See more at 3.2 Dimension
Tolerance: 4.5g
M eet industrial level
Standard 50 Ω characteristic impedance
It is recommended to use 12V or 24V
Standard DB9 hole / 3.81 terminal block
from 1200 to 115200 bps
65536 configurable addresses
9

Advertisement

Table of Contents
loading