Design And Function; Transport And Installation; Ambient Conditions; In Operation - EWM Degauss 600 Operating Instructions Manual

Degaussing machine
Table of Contents

Advertisement

Design and function

Transport and installation

5
Design and function
Risk of injury from electrical voltage!
Contact with live parts, e.g. power connections, can be fatal!
Observe the safety information on the first pages of the operating instructions!
Commissioning must be carried out by persons who are specifically trained in handling
power sources!
Connect connection or power cables while the machine is switched off!
Read and observe the documentation to all system and accessory components!
5.1
Transport and installation
Risk of accident due to improper transport of machines that must not be lifted!
Do not lift or suspend the machine! The machine can drop and cause injuries! The
handles, straps or brackets are suitable for transport by hand only!
The machine must not be suspended or lifted using a crane.
5.1.1

Ambient conditions

The machine may only be placed and operated on a suitable, load-bearing and even surface (ac-
cording to IP 34s in case of outside operation as well)!
Ensure the machine is operated on an even, anti-slip floor and provide sufficient lighting of the
work area.
Safe operation of the machine must be guaranteed at all times!
Equipment damage due to contamination!
Unusually high amounts of dust, acids, corrosive gases or substances can damage the machine
(observe maintenance intervals > see 6.2 chapter).
Avoid large amounts of smoke, steam, oily fumes, grinding dust and corrosive ambient air!
5.1.1.1

In operation

Temperature range of the ambient air:
-25 °C to +40 °C (-13 °F to 104 °F)
Relative humidity:
up to 50 % at 40 °C (104 °F)
up to 90 % at 20 °C (68 °F)
5.1.1.2

Transport and storage

Storage in a closed room, temperature range of the ambient air:
-30 °C to +70 °C (-22 °F to 158 °F)
Relative humidity
up to 90 % at 20 °C (68 °F)
[1]
Ambient temperature dependent on coolant! Observe the coolant temperature range of the torch coo-
ling
5.1.2

Machine cooling

Insufficient ventilation results in a reduction in performance and equipment damage.
Observe the ambient conditions!
Keep the cooling air inlet and outlet clear!
Observe the minimum distance of 0.5 m from obstacles!
18
WARNING
WARNING
[1]
[1]
099-002065-EW501