Page 1
Dreamline PREMIUM FI INSTALLATION AND USER MANUAL for your heat pump www.poolstar.fr...
Page 2
Warning This heat pump contains a flammable refrigerant R32. Any intervention on the refrigerant circuit is prohibited without a valid authorization. Before working on the refrigerant circuit, the following precautions are necessary for safe work. 1. Work procedure The work must be carried out according to a controlled procedure, in order to minimize the risk of presence of flammable gases or vapors during the execution of the works.
Page 3
These are the result of many years of research in the field of design and production of heat pumps for swimming pools. Our aim is to provide you with an exceptional high performance quality product. We have produced this manual with the utmost care so that you get maximum benefit from your Poolex heat pump.
Page 4
They must be given to the installer and retained by the user. If the manual is lost, please consult the website: www.poolex.fr The instructions and recommendations contained in this manual should be read carefully and understood since they provide valuable information concerning the heat pump’s safe handling and operation. Keep this manual in an accessible place for easy future reference.
1. General General Terms of Delivery All equipment, even if shipped ‘free of carriage and packing’, is dispatched at the consignee’s own risk The person responsible for receiving the equipment must carry out a visual inspection to identify any dam- age to the heat pump during transport (refrigerant system, body panels, electrical control box, frame).
The low and high side test pressure must not exceed 42 bar. Water treatment Poolex heat pumps for swimming pools can be used with all types of water treatment systems. Nevertheless, it is essential that the treatment system (chlorine, pH, bromine and/or salt chlorinator meter- ing pumps) is installed after the heat pump in the hydraulic circuit.
4 anti-vibration pads (fastenings not supplied) ✔ General characteristics A Poolex heat pump has the following features: CE certification and complies with the RoHS European directive. High performance with up to 80% energy savings compared to a conventional heating system.
2. Description Unit dimensions Dimensions in mm Model Jetline Premium FI 55 / 75 Jetline Premium FI 95 / 125 / 155 Jetline Premium FI 210 / 210 Tri 1084...
2. Description Exploded view 1. Aluminum front panel 14. Right structure 2. Air deflector 15. Manometer 3. Fan propeller 16. Right Panel 4. Left panel 17. Control panel 5. Left structure 18. Electrical terminal cover 6. Fan motor 19. Electrical terminal block 7.
3. Installation WARNING: Installation must be carried out by a qualified engineer. This section is provided for information purposes only and must be checked and adapted if necessary according to the actual installation conditions. Pre-requirements Equipment necessary for the installation of your heat pump: Power supply cable suitable for the unit’s power requirements.
3. Installation WARNING: Installation must be carried out by a qualified engineer. This section is provided for information purposes only and must be checked and adapted if necessary according to the actual installation conditions. Hydraulic connection By-Pass assembly Open valve The heat pump must be connected to the pool by Half-open valve means of a By-Pass assembly.
Page 15
3. Installation By-Pass assembly for one heat pump TOWARDS THE POOL Automated treatment system POOL Filtration + Pump FROM THE POOL Half-open valve Open valve By-Pass assembly for more than one heat pump TOWARDS THE POOL Automated treatment system POOL Filtration + Pump FROM THE POOL Half-open valve...
Dreamline Premium FI 210 27.1 A RO2V 3x6 mm² 30 A Triphasé Dreamline Premium FI 210 Tri 27.1 A RO2V 5x2.5 mm² 30 A 380-415V/3N~50Hz Cable cross-section suitable for max. length 10 metres. For longer than 10 metres, consult an electrician.
3. Installation Electrical connection WARNING: The heat pump’s power supply MUST be disconnected before any operation. Please comply with the following instructions to electrically connect the heat pump. Step 1: Detach the electrical side panel with a screwdriver to access the electrical terminal block. Step 2: Insert the cable into the heat pump unit by passing it through the opening provided for that purpose.
3. Installation Wired remote control Set temperature Water temperature Defrosting WiFi Operating mode °C °C Button: Clock / Programming Clock Button: Operating mode Button: On / Off Before you start, make sure the filtration pump is running and that water is flowing through the heat pump.
4. Use Start-up and locking Press the button to switch the heat pump on or off. This button is also used to return to the main interface. When the heat pump is in operation, press the button for 5 seconds to lock or unlock the housing. (The lock is activated automatically after 60 seconds of inactivity).
4. Use Choice of operating mode WARNING: Before starting, ensure that the filtra- tion pump is operating correctly. Step 1 : Go to the main menu by unlocking the control panel. °C °C Étape 2 : Presse the button to switch between the 3 operating modes: Eco Inverter, Boost Inverter, refroidisse- ment.
4. Use Clock setting Step 1 : Go to the main menu by unlocking the control panel. Step 2 : Push the button to enter the clock setting interface. Clock display flashes. Step 3 : Change the hours using the buttons °C °C Step 4 : Press again...
4. Use Activation / deactivation of On / Off groups Groups can be activated / deactivated at any time. The setting is as follows: Step 1 : Go to the main menu by unlocking the control panel. Step 2 : Press the button for 5 seconds to enter °C °C...
Page 23
4. Use Table of main parameters N° Description Default value Variation Adjusting the heating temperature 27°C 15 - 40°C Adjusting the cooling temperature 27°C 8 - 28°C Reserved - Do not adjust Adjustment of temperature difference before restart 1°C 1-18°C Stop once the temperature is reached 1=ON ;...
5. Operation Operation Conditions of use For the heat pump to operate normally, the ambient air temperature must be between -5°C and 43°C. Recommendations prior to start-up Before activating the heat pump, please: Check that the unit is firmly secured and stable. ✔...
5. Operation Using the pressure gauge The gauge is for monitoring the pressure of the refrigerant contained in the heat pump. The values it indicates can vary considerably, depending on the climate, temperature and atmospheric pressure. When the heat pump is in operation: The gauge’s needle indicates the refrigerant pressure.
6. Maintenance and servicing Maintenance and servicing WARNING: Before undertaking maintenance work on the unit, ensure that you have disconnected the electrical power supply. Cleaning The heat pump’s casing must be cleaned with a damp cloth. The use of detergents or other household products could damage the surface of the casing and affect its properties.
7. Repairs WARNING: Under normal conditions, a suitable heat pump can heat the water in a swimming pool by 1°C to 2°C per day. It is therefore quite normal to not feel any temperature difference in the system when the heat pump is working. A heated pool must be covered to avoid any loss of heat.
7. Repairs List of faults Code Anomalies Causes possibles Actions Check your water circuit operation and the opening of the By-Pass Insufficient water in heat exchanger valves Flow sensor malfunction Sensor disconnected or defective Reconnect or replace sensor Protection activated when the ambient temperature is too low and Antifreeze protection No intervention is necessary the unit is on standby...
8. Recycling Recycling the heat pump Your heat pump has reached the end of its life and you wish to dispose of it or to replace it. Do not throw it in the rubbish bin. A heat pump must be disposed of separately with a view to its reuse, recycling or upgrading. It contains substances that are potentially hazardous to the environment but which will be eliminated or neutralised by recycling.
The Poolstar Company guarantees the original owner against defective materials and faults in the manufac- ture of the Poolex Jetline Dreamline Premium Fi heat pump for a period of three (3) years. The compressor is guaranteed for a period of seven (7) years.