Operating manual Control terminal AmaLog+ Please read and observe this operating manual before initial MG3828 operation of the implement! BAH0017.6 08.19 Keep it in a safe place for future use!
Page 2
READING THE INSTRUCTION manual and to adhere to it should not appear to be inconvenient and superfluous as it is not enough to hear from others and to realise that a machine is good, to buy it and to believe that now everything would work by itself.
Page 3
+ 49 (0) 5405 50 1-0 E-mail: amazone@amazone.de Spare part orders Spare parts lists are freely accessible in the spare parts portal at www.amazone.de. Please send orders to your AMAZONE dealer. Formalities of the operating manual Document number: MG3828 Compilation date: 08.19 ...
Page 4
Foreword Dear Customer, You have chosen one of the quality products from the wide product range of AMAZONEN-WERKE, H. DREYER GmbH & Co. KG. We thank you for your trust in our products Before initial operation, read and observe this operating manual, and particularly the safety information.
User information ..................7 Purpose of the document ......................7 Locations in the operating manual ................... 7 Diagrams ..........................7 General safety instructions ................. 8 Obligations and liability ......................8 ...
User information User information The User Information section provides information on use of the oper- ating manual. Purpose of the document This operating manual describes the operation of the control terminal provides important information on safe and efficient handling ...
General safety instructions General safety instructions This section contains important instructions for operating the control terminal safely. Obligations and liability Comply with the instructions in the operating manual Knowledge of the basic safety instructions and safety regulations is a basic prerequisite for safe handling and fault-free operation of the control terminal.
General safety instructions Safety-conscious working Besides the safety information in this operating manual, the generally applicable national workplace safety and accident prevention regula- tions are binding. Handling the product Do not subject the control terminal to any mechanical vibrations or impact.
General safety instructions Representation of safety symbols Safety instructions are marked with the triangular safety symbol and the preceding signal word. The signal word (DANGER, WARNING, CAUTION) describes the severity of the risk, and carries the following meaning: DANGER Indicates a direct threat at high risk which will result in death or most serious bodily harm (loss of limbs or long-term harm), should it not be prevented.
Product description Product description Fig. 1 Standard equipment Fig. 1/... Special equipment Fig. 1/... (1) Control terminal with fastening bracket (4) Bracket with battery cable choice of (2) Socket connection, 12V one or two sockets (3) Wiring harness with 20-pin connector AMALOG BAH0017.6 08.19...
Product description Intended use The control terminal is intended exclusively for conventional use as a display and monitoring device in agricultural applications. Intended use also includes observing all instructions in this operating manual. Other uses to those specified above are forbidden and shall be considered as improper. For any damage resulting from improper use ...
Layout and function Layout and function The following section provides information on the structure of the control terminal and the functions of the individual components. The control terminal has 6-digit display (Fig. 3/1). The control terminal is equipped with an EEPROM (memory chip) for storing data.
Layout and function Operation with seed drills The AmaLog+ measures the covered part area [ha]. stores the cultivated total area [ha]. indicates the forward speed [km/h]. controls the tramline control and the tramline marker indicates the position of the hydraulically operated track markers ...
Layout and function 4.3.2 Operation with pneumatic seed drills AmaLog+ monitors the tramline control in the dis- tributor head (Fig. 5/1). An acoustic alarm sounds in the event of incorrect shutter position. Fig. 5 AmaLog+ monitors the fan speed. If the actual speed deviates by more than 10 % from the target speed, an acoustic signal is initi- ated and in the display the control lamp (Fig.
Layout and function Work display The work display (Fig. 7) appears with the first pulse from the distance sensor. The flashing circle symbol (Fig. 7/1) during work indicates that The control terminal receives pulses from the distance sensor The control terminal is working correctly.
Page 17
Layout and function Fig. 8/… Display and/or control symbol sensor Forward speed [km/h] pulses from the distance sensor Tramline counter position Control terminal data Left track marker Control symbol in working position pulse, e.g. from track marker sensor Right track marker Control symbol in working position Display appears automatically in event of faults:...
Layout and function Button assignment Button Button assignment Button Button assignment Switching on/off Correction button Data input confirmation Reduction Increasing of the value displayed of the value displayed Input/display Input/display of of a soil-dependent number of working width [m] pulses of a 100 m-long calibration distance Input/display Input of tramline rhythm...
Layout and function Creation of tramlines As described in the operating manual for the seed drill, the tramline control allows the creation of tram- lines at pre-selected intervals on the field. When creating the tramlines the tramline counter shows the number "0" on the control terminal ...
Page 20
Layout and function The creation of tramlines is shown in Figure (Fig. 10) using various examples: Working width of the seed drill Tramline spacing (= working width fertiliser spreader/field sprayer) Tramline rhythm (entered on the control terminal) D = Tramline counter (during operation, the field passes are numbered consecutively and displayed on the control terminal).
Page 21
Layout and function Fig. 10 AMALOG BAH0017.6 08.19...
Commissioning Commissioning Installing the control terminal 1. Screw the bracket (Fig. 11/1) so that is free from vibrations and electrically connected to the right of the driver's position in the tractor cab, within visual range and easy to access (Fig. 11/2). The distance from the radio unit or aerial must be at least 1 m.
Commissioning 2. Insert the power cable (Fig. 13/1) into the bracket and the 12V tractor socket. 3. Connect the bracket and the control termi- nal with the power cable (Fig. 13/2). 4. Couple the seed drill or soil tillage imple- ment to the tractor vehicle (see operating manual for seed drill or soil tillage imple- ment).
Settings Settings Enter implement data The control terminal requires input of the implement data in coded form (see Fig. 14). Refer to the machine data in the table (see section "Machine data table", Seite 37). Digit 1 (1) shows the mode Digit 2 (2) shows the coding Fig.
Settings Displaying / altering the working width 1. Press Display: stored working width [m], e.g. 3.0 m (Fig. 15). 2. Change the working width [m] with the buttons. Fig. 15 3. Press Store the selected value. Displaying / altering the target blower fan speed (during standstill) This setting is only possible for pneumatic seed drills.
Settings Displaying / altering the target blower fan speed (during operation) This setting is only possible for pneumatic seed drills. 1. Press the button (blue). Display of (Fig. 17) current blower fan speed (e.g. 3600 [rpm.]). Fig. 17 2. Press the button and button (yellow) simultaneously.
Settings Calibration value (pulses per 100 m) The control terminal requires the calibration value "Pulses per 100 m" to determine the forward speed [km/h] determine the worked area [ha]. If the calibration value is unknown, determine the "pulses per 100 m" calibration value by means of a calibration run (see section "Determining / storing the calibration value (pulses per 100 m)", unterhalb).
Settings 6. Stop after exactly 100 m. The display (Fig. 20) shows the calibration value (e.g. 1005 imp./100 m). 7. The determined calibration value can be en- tered in the table, Seite 43. 8. Press Store the calibration value (imp./100 m). Fig.
Settings 6.5.3 Calculating the number of crank turns for the calibration test If the calibration value differs from the values in the Table (see Chap. 9.3, Seite 40) recalculate the number of crank turns for the calibration test (see below) ...
Work commencement Work commencement 1. Place machine in starting position (standstill). Display at standstill: Digit 1 (Fig. 22/1) shows the travel speed (0 km/h). Digit 2 (Fig. 22/2) shows the tramline counter 4. Fig. 22 2. Lower the correct track marker (see seed drill operating manual). The tramline control can be coupled with the track marker control.
Work commencement Tramline counter 7.1.1 Setting the tramline counter Press the button several times until the right tramline counter is displayed [e.g.: Tramline counter 2, see Seite 21, Fig. 10, under the lettering "START"]. 7.1.2 Block the tramline counter Press ...
Work commencement Worked area 7.2.1 Displaying the worked part area Press Display (Fig. 24): worked part area (e.g. 10.5 ha). Fig. 24 7.2.2 Erasing the part area memory 1. Press and hold the button. 2. Press The part area memory is set to 0 [ha]. 3.
Work commencement Display during work During operation, the AmaLog+ shows the travel speed (Fig. 26/1), e.g. 6.9 km/h the setting of the tramline counter (Fig. 26/2), e.g. Switching position 3 the left track marker (Fig. 26/3) is in the working position ...
Faults Faults Fault display A3 Tramline fault message The occurrence of a tramline fault activates the display (Fig. 28) an acoustic signal. Fig. 28 Fault display A4 Alarm message at standstill of the universal joint shaft of the active soil tillage implement (e.g.
Page 35
Faults Fault display A5 Alarm message in the event of insufficient seed quantity for machines with fill level sensor in the event of a malfunction of the seed seeding shaft only on DMC Primera, Condor and Citan 01 ...
Page 36
Faults Fault display A6 (DMC Primera, Condor and Citan 01 only) Alarm message in the event of insufficient fertiliser in the event of a malfunction of the ferti- liser seeding shaft In the event of an alarm the display (Fig.
Page 37
Tables Tables Machine data table Mode 1 Code Activating functions of the control terminal Activate all functions of the control terminal Only activate the hectare counter of the control terminal Mode 2 Code Number of track marker sensors Machine with 2 track marker sensors, e.g.
Page 38
Tables Mode 3 Code Implement type D9 Super/Special D9 6000 TC Cam wheel seed drills Cataya Special D9 Super/Special Cam wheel seed drills D9 6000 TC with seed shaft monitoring Cataya Special AD-P Pneumatic seed drills Citan 6000 Pneumatic seed drills Citan 01 With 2 separate hoppers and Condor...
Page 39
Tables Table for adjustable tramline rhythms Tramline rhythms Fig. 37 Tramline rhythms * No tramlines are created Fig. 38 AMALOG BAH0017.6 08.19...
Page 40
Tables Tables: calibration values / crank turns (guide values) The table values in the Chapter are guide values. If the actual calibration value (imp./100 m) deviates from the table value, the number of crank turns for the calibration test will also change.
Page 41
Tables Pneumatic seeding technology Working width 2.5 m 3.0 m 3.5 m 4.0 m Pack top seed drills Calibration value (pneumatic) (imp./100 m) Crank turns on 1/40 ha AD-P 03 Special 1409 38.5 33.0 29.0 with star wheel drive AD-P 03 Super ...
Page 42
Tables Predecessor machines Working width 2.5 m 3.0 m 4.0 m Pack top seed drills Calibration value (mechanical) (imp./100 m) Crank turns on 1/40 ha AD 03 27.0 22.5 17.0 RP-AD 03 59.0 49.0 37.0 Working width 2.5 m 3.0 m 4.0 m Pack top seed drills Calibration value...
Page 43