7.6 Pulse width trigger
This is the mode to set the exposure period by the pulse width of the trigger signal ap-
plied to the DIGITAL terminal. This accumulates electric charge taking the trigger signal
"L" period as exposure time, and developes a 1-frame image. The trigger signal mini-
mum pulse width ("L" period) is 20 s (1/50000s).
Input signal: Trigger
Output signal: Video data, pixel clock, FEN/VD, LEN/HD
Trigger
Video data
(video period image)
7.7 Pulse width trigger partial readout
This is the mode for partial scanning by the pulse width trigger operation.
Input signal: Trigger
Output signal: Video data, pixel clock, FEN/VD, LEN/HD
Trigger
Video data
(video period image)
FEN
LEN
14
Exposure period
HD
VD
FEN
LEN
Exposure period
HD
VD