Graco PRO Auto Xs Series Instructions-Parts List Manual page 23

Automatic electrostatic air spray gun
Table of Contents

Advertisement

Daily Care and Cleaning,
continued
WARNING
Pressurized Equipment Hazard
To reduce the risk of an injury, follow the
Pressure Relief Procedure on page 17
before doing any maintenance on the gun
or system.
Clean the fluid and air line filters daily.
Clean the outside of the gun daily with a soft cloth
dampened in a compatible solvent.
Clean the air cap and fluid nozzle daily, minimum.
Some applications require more frequent cleaning.
Replace the fluid nozzle and air cap if they are dam-
aged. See Clean the Air Cap and Fluid Nozzle,
page 24.
309297K
Check the electrode and replace if broken or dam-
aged. See Electrode Replacement on page 35.
Check for fluid leakage from the gun and fluid
hoses. See Check for Fluid Leakage on page 25.
Tighten fittings or replace equipment as needed.
Flush the gun before changing colors and whenever
you are done operating the gun.
WARNING
Fire, Explosion, and Electric Shock Hazard
To reduce the risk of fire, explosion, or elec-
tric shock, turn off the turbine air (TA)
before flushing the gun or any part of the
system.
Maintenance
23