7. Manual Temperature Setting

Press + or - to set the temperature, then press
or wait for 15 seconds before the values are accepted. The
symbol
is displayed. The thermostat will run following this value until the program changes or until the
key
. The display shows alternatively clock and the time remaining to return to the program.

8. Temperature Calibration

Hold down the
key for 5 seconds to enter the operation mode selection, then press the
key and
the option opens to calibrate the temperature "CAL" (from -3 °C to + 3 °C in 0.5 °C increments). Use the + and
- keys to set the desired value and press the
key to confirm.
9. Backlight
The backlight turns on when the dial is used and turns off after 15 s of inactivity.
10. Battery Replacement
The average battery life is 1 year, but it can be significantly reduced if backlight is often switched on. When
the low battery symbol
appears on the display, the batteries need to be replaced. Battery replacing will
cause loss of preset time.
11. Permanent Temperature / Holidays
Press + or -, the temperature will flash. Then press
to enter continuous temperature mode. Confirm
changes by pressing
or wait 15 seconds for the values to be accepted. The temperature set in this way
will remain in effect until you terminate it by pressing
.

12. Reset to Factory Settings

Remove the back cover and remove the batteries, press and hold the key
on the front panel. Insert the
batteries, the display will light up and show all symbols, then release the button and the thermostat will
return to factory settings.
13. El. Wiring
The thermostat controls the boiler or A/C via a potential-free relay: 1 (NC), 2 (COM), 3 (NO).
Rear side of the front panel