Toshiba Adjustable Speed Drive H3 Operation Manual page 18

Variable torque adjustable speed drive
Table of Contents

Advertisement

Standard Connection Diagrams (cont'd)
INPUT POWER SUPPLY
(set by input power selection)
INPUT POWER SELECTION
415/460V-50/60Hz
400/440V-50/60Hz
380V-50Hz
PROGRAMMABLE
SIGNAL INPUT
PROGRAMMABLE
ANALOG INPUT
-
+
-
+
NOTE:
1.)
As an example, the "S4" terminal is shown above as an EMERGENCY OFF input. See
Section 8 for information on how to program the drive for this and other functions.
TOSHIBA
TOSVERT-130H3
STANDARD CONNECTION
MODEL 4400 TO 430K
MCCB
L1(R)
L2 (S)
L3 (T)
R41/46
R40/44
R38
RJ
RES
F
R
ST
S1
S2
S3
DIGITAL
PP
OPERATION PANEL
RR
CC
IV
RX
GND(E)
4 - 2
T1(U)
T2 (V)
T3 (W)
(see note 1 below) S4
CC
FLA
FLB
FLC
R/CH-A
R/CH-C
LOW-A
LOW-C
P24
FP
FM
AM
CC
PROGRAMMABLE
OUTPUT CONTACTS
250V, 2A MAX
PROGRAMMABLE
OUTPUT CONTACTS
250V, 2A MAX
50mA MAX
PULSE OUTPUT
PROGRAMMABLE
SIGNAL OUTPUT
0-1mA or 4-20mA