Table of Contents

Advertisement

Quick Links

U s e r
d o c u m e n t a t i o n
TFT/HBxxxPU71x16-xxx
TFT/HVxxxPU71x16-xxx
Document Order code: DOC/Protouch-71
Revision
Date
1.0
28.01.2014
Author
Modification
F. Liechti
Initial Release

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TFT/HB PU71 16 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for syslogic TFT/HB PU71 16 Series

  • Page 1 U s e r d o c u m e n t a t i o n TFT/HBxxxPU71x16-xxx TFT/HVxxxPU71x16-xxx Document Order code: DOC/Protouch-71 Revision Date Author Modification 28.01.2014 F. Liechti Initial Release...
  • Page 2: Table Of Contents

    Benefits of Syslogic`s Projected capacitive touch panels 2.1.2. Intended use of Projected Capacitive Touch Panels 2.2. Device Variants 2.3. Accessories 2.4. Features 2.4.1. HBxxxPU7F16-xxx 2.4.2. HVxxxPU71x16-xxx 3 Hardware Description 3.1. Overview 3.2. Dimensions © Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com...
  • Page 3 Operating systems 5 Technical Data 5.1. General Electrical Data 5.2. EMI / EMC Specification 1.1.1. Emission 1.1.2. Immunity 5.3. Environmental Specification 6 Product Revision History 6.1. Hardware 7 Manufacturer Information 7.1. Contact © Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com...
  • Page 4 Tab. 14 Environmental Specification Tab. 15 Hardware Revision State List of Figures Fig. 1 HBxxxPU71x16-xxx Fig. 2 HVxxxPU7F16-xxx Fig. 3 Required Cut out HVxxxPU7F16-xxx Fig. 4 Screws to hold the mounting Frame © Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com...
  • Page 5: Introduction

    Note that the documentation for the products is constantly revised and improved. The right to change this documentation at any time without notice is therefore reserved. Syslogic is grateful for any help referring to errors or for suggestions for improvements. The following registered trademarks are used:...
  • Page 6: Information Pictograms Indicate The Following

    Syslogic Datentechnik AG. Syslogic Datentechnik AG does not accept any liability for damages arising from the use of any incorrect or incomplete information contained in this documentation or any information missing.
  • Page 7: Items Delivered

    7). Do not use or install the product if you are in doubt. In any case of misuse of the product, the user is solely liable for the consequences. 1.7.1. Important note This is a Class A product and not intended to be used in domestic environment. The product may cause electromagnetic interference. Appropriate measures must be taken. © Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com...
  • Page 8: Battery

    The main functionality of the product is defined by the application program. The application program is not part of the delivery by Syslogic but are defined, developed and tested by the customer or a system-integrator for each specific application. Refer to the respective documentation for more information.
  • Page 9: Warranty

    The warranty does not include damage due to errors in firmware or software delivered with the products. 1.9.7. RoHS The product is designed and produced according to the Restriction of Hazardous Substances (RoHS) Directive (2002/95/EC). © Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com...
  • Page 10: Product Description

    This device description is designed as a reference guide for the installation, connection, operation and maintenance of all versions of the Projected Capacitive Panel, and also provides all the relevant technical data. © Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com...
  • Page 11: Device Variants

    Order code Type designation Description TouchDriver Touch driver software Touch driver software for Windows 9x / Me / 2000 / XP / 7 / Embedded Tab. 3 Projected capacitive touch panel accessories © Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com...
  • Page 12: Features

    Supply Ethernet 2 COM1 RS232, Rs485 or RS232 Fig. 1 HBxxxPU71x16-xxx 2.4.2. HVxxxPU71x16-xxx Ground USB 0-3 Terminal Power Supply Display Ethernet 1 COM1 RS232, Rs485 or Ethernet 2 RS232 Fig. 2 HVxxxPU7F16-xxx © Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com...
  • Page 13: Hardware Description

    W [mm] W1 [mm] W2 [mm] H [mm] H1[mm] H2 [mm] D1 [mm] D2 [mm] TFT/HB104PU71x16-xxx 71.5 59.5 TFT/HB121PU71x16-xxx 52.6 53.6 59.5 TFT/HB150PU71x16-xx 84.7 83.7 150.7 29.5 61.5 Tab. 4 HBxxxPU71x16-xxx dimensions © Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com...
  • Page 14: Hvxxxpu71X16-Xxx

    H [mm] H1 [mm] H2 [mm] D1 [mm] D2 [mm] D3 [mm] TFT/HV104PU71x16-xxx 39,5 24.5 58.8 TFT/HV121PU71x16-xxx 26,5 26,5 265bb 67,5 24.5 58.8 TFT/HV150PU71x16-xxx 57,5 57,5 104,5 27.5 61.5 Tab. 5 HVxxxPU71x16-xxx dimensions © Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com...
  • Page 15: Mounting

    Tab. 6 TFT/HBxxxPU71x16-xxx Mounting dimensions Fig. 3 Required Cut out HVxxxPU7F16-xxx Mounting Angle: Mounting Angle must be 90° Cooling Space: To ensure cooling leave at least 10cm of free space around product. © Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com...
  • Page 16: Fig. 4 Screws To Hold The Mounting Frame

    Insert the projected capacitive touch panel from the front into the cut out and make sure that the sealing fits properly. Reattach the mounting frame and fix it into place by reattaching the screws highlighted in red. The product is now installed properly. Wall Projected capacitive touch panel © Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com...
  • Page 17: Tft/Hvxxxpu71X16-Xxx

    Mounting Angle must be 90° ± 15° Cooling Space: To ensure cooling leave at least 10cm of free space around product. For best thermal performance use spacer M4 x 5mm between the VESA mounting frame and the device © Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com...
  • Page 18: Service Cover

    To remove the Service Cover remove the two Philips screws highlighted in red and remove the cover. After removing the cover the battery and the C-Fast slot are accessible. battery C-Fast Slot Please install the Service Cover before operating the Projected Capacitive Touch Panel. © Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com...
  • Page 19: Interfaces

    When using the On Screen Keyboard (OSK) for Tablet Computer TabTip.exe under Windows 7 you need to use the original Windows7 driver that is automatically installed instead of the separate touch driver provided by Syslogic to allow TabTip.exe to work properly.
  • Page 20: Touch Screen Calibration Using Windows 7 Touch Driver

    DumpPort (Windows 7, WINIO_v3) to access the register. Value Signal Remarks 0xFF Maximum Brightness (default) 0x10-0xFE Brightness from dark to bright 0x00 Backlight turned off Tab. 9 Meaning of the backlight register. © Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com...
  • Page 21: Programming Information

    DOC/Protouch-71; V1.0 4 Programming Information 4.1. Overview For details regarding the integrated IPC see separate product documentation DOC/COMPACT71-MLE. 4.1. Operating systems Syslogic offers an implementation for the following operating systems (OS): Debian Linux Distribution IPC/DEBIAN-60A Microsoft Windows Embedded Standard 2009...
  • Page 22: Technical Data

    Tcomp °C Tab. 11 General Recommended Operating Conditions 50% CPU Load, 2 x GBit Ethernet connected, 100% Backlight. 30% CPU Load, 2 x GBit Ethernet connected, 80% Backlight for 5min, 10min off © Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com...
  • Page 23: Tab. 11 General Electrical Characteristics

    TFT/Hx150PU71G16-A103E 2800 full load power dissipation (at 24V input voltage) Pmax TFT/Hx104PU71G16-A103E 22.5 TFT/Hx121PU71G16-A103E 24.6 TFT/Hx150PU71G16-A103E 25.5 Tab. 12 General Electrical Characteristics 50% CPU Load, 2 x GBit Ethernet connected, 100% Backlight © Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com...
  • Page 24: Emi / Emc Specification

    Mains AC EN55022:2010 0.15 – 0.5MHz: 79dBuV (QP) CISPR 22:2008 0.5 – 30MHz: 73dBuV (QP) Telecommunication ports 0.15 – 0.5MHz: 97 to 87dBuV (QP) 0.5 – 30MHz: 87dBuV (QP) Tab. 13 Emission requirements © Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com...
  • Page 25: Immunity

    Criterion A Tab. 14 Immunity requirements 5.3. Environmental Specification Parameter Symbol Unit storage temperature range 75 °C Operating altitude 2000 MAMSL Humidity4 (not condensing) Tab. 15 Environmental Specification above +60°C: < 133.8g/m3 © Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com...
  • Page 26: Product Revision History

    DOC/Protouch-71; V1.0 6 Product Revision History 6.1. Hardware For details regarding the integrated IPC see separate product documentation DOC/COMPACT71-MLE Hardware Revision Product Remarks Revision TFT/HxxxPU71x16-xxx 1.0 first release Tab. 16 Hardware Revision State © Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com...
  • Page 27: Manufacturer Information

    Syslogic Datentechnik AG Taefernstrasse 28 CH-5405 Baden-Daettwil / Switzerland Email: support@syslogic.com www: http://www.syslogic.com/ Fax: +41 56 200 9040 Tel: +41 56 200 9050 © Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com...