syslogic C Series User Documentation

Hide thumbs Also See for C Series:
Table of Contents

Advertisement

Quick Links

user documentation
TFT/HB101PU81xxx-C001y
Document Ordercode: DOC/C-Series_Touch-PC
Revision
Date
0.1
16.11.2018
0.2
21.11.2018
0.3
06.03.2019
1.0
08.04.2019
1.1
07.06.2019
DOC_C-Series_Touch-PC_V1.1.docx
© 2019 Syslogic Datentechnik AG | All rights reserved
Author
Modification
D. Lagler
Preliminary version
D. Lagler
Spelling corrections
D. Lagler
Added maintenance part and operating conditions
D. Lagler
Added pinout of mPCIe and m.2, defined use cases
D. Lagler
Mounting instructions and power consumption revised
Page 1 of 37

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for syslogic C Series

  • Page 1 Added maintenance part and operating conditions 08.04.2019 D. Lagler Added pinout of mPCIe and m.2, defined use cases 07.06.2019 D. Lagler Mounting instructions and power consumption revised DOC_C-Series_Touch-PC_V1.1.docx Page 1 of 37 © 2019 Syslogic Datentechnik AG | All rights reserved...
  • Page 2: Table Of Contents

    X2 (for future use; only on selected produtcts) 2.4.5 USB Interface 2.4.6 Ethernet LAN Interface 2.4.7 Display 2.4.8 Frontside Status LEDs 2.4.9 Antennas (only on selected products) DOC_C-Series_Touch-PC_V1.1.docx Seite 2 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 3 General Electrical Data EMI / EMC Specification Mechanical Data 4.3.1 TFT/HB101PU81xxx-C001y Use cases 5 Firmware Software Structure Firmware Functions Application Programming Interface (API) Supported Operating System DOC_C-Series_Touch-PC_V1.1.docx Seite 3 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 4 Additional grounding of the cable shields at the entry point of a cabinet Fig. 7 Isolated communication link Fig. 8 Non-isolated communication link with common chassis potential Related Documents DOC_C-Series_Touch-PC_V1.1.docx Seite 4 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 5: Introduction

    Note that the documentation for the products is constantly revised and improved. The right to change this documentation at any time without notice is therefore reserved. Syslogic is grateful for any help referring to errors or for suggestions for improvements. The following registered trademarks are used:...
  • Page 6: Information Pictograms Indicate The Following

    Syslogic Datentechnik AG. Syslogic Datentechnik AG does not accept any liability for damages arising from the use of any incorrect or incomplete information contained in this documentation or any information missing.
  • Page 7: Items Delivered

    To fullfill class A of EN55032 and EN55035 a CE-compliant AC/DC power supply must be used. Cable length between power supply and device is limited to 3m. DOC_C-Series_Touch-PC_V1.1.docx Seite 7 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 8: Electro Static Discharge

    The main functionality of the product is defined by the application program. The application program is not part of the delivery by Syslogic but is defined, developed and tested by the customer or a system-integrator for each specific application. Refer to the respective documentation for more information.
  • Page 9: Disposal

    The products of the C-Series Touch-PC family are not designed ready for operation for the end-user and are not intended for consumer applications. According to Waste Electrical and Electronic Equipment (WEEE) Directive (2002/96/EC) Syslogic takes back defective devices for proper disposal at the point of sale.
  • Page 10: Product Description

    Intel x5-E3930 dual core 1.8GHz 64GB TFT/HB101PU81H18-C001E 10.1” WXGA Flush mounting Intel x5-E3940 quad core 1.8GHz 64GB TFT/HB101PU81I20-C001E 10.1” WXGA Flush mounting Intel x7-E3950 quad core 2.0GHz 64GB DOC_C-Series_Touch-PC_V1.1.docx Seite 10 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 11: Accessories

    Projected capacitive touch panel accessories Features 2.4.1 TFT/HB101PU81xxx-C001y Ground USB 3.0 Terminal Power Display Supply Status LEDs Fig. 1 TFT/HB101PU81xxx-C001y (Front) ANT2 ANT1 ANT3 Fig. 2 TFT/HB101PU81xxx-C001y (Back) DOC_C-Series_Touch-PC_V1.1.docx Seite 11 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 12: Power Supply

    Maximum cable length allowed for X1 connection is 2.8 m. If longer cables are used, special overvoltage and filtering elements must be installed to comply with the requirements of EMI/RFI -certification. Only use high quality industrial devices with sufficient EMI compatibility. DOC_C-Series_Touch-PC_V1.1.docx Seite 12 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 13: X2 (For Future Use; Only On Selected Produtcts)

    Maximum cable length allowed for display connection is 3 m. If longer cables are used, special overvoltage and filtering elements must be installed to comply with the requirements of EMI/RFI -certification. Only use high quality industrial devices with sufficient EMI compatibility. DOC_C-Series_Touch-PC_V1.1.docx Seite 13 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 14: Frontside Status Leds

    The C-Series Touch-PC offers two USB2.0 ports on Micro-Lock Plus headers from Molex. One port is used to connect the touchpanel to the PC board. USB 6 (P5) USB 7 (P7) Signal Signal USB6- USB7- USB6+ USB7+ Tab. 6 Pinout internal USB ports DOC_C-Series_Touch-PC_V1.1.docx Seite 14 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 15: Slot

    +3.3V Tab. 7 Pinout m.2 Important Note By default, an m.2 2242 flash memory module is mounted on this port By default SATA signals are selected DOC_C-Series_Touch-PC_V1.1.docx Seite 15 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 16: Mpcie Slot

    Display brightness can be manipulated by using the driver interfaces in the operating system. For further details on manipulating display brightness refer to the manual of the operating system. By default PCIe signals are selected DOC_C-Series_Touch-PC_V1.1.docx Seite 16 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 17: Maintenance

    Make sure the device has cooled down to room temperature Only open the device in an ESD protected area 2.7.1 Opening the device Loosen the four screws fixing the housing Tool: Torx screwdriver T10 DOC_C-Series_Touch-PC_V1.1.docx Seite 17 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 18: Re-Assemble The Device

    Be careful not to tear the cables for display and touch Detach the cables to the display and touch 2.7.2 Re-assemble the device To re-assemble the device, follow 2.7.1 in reverse order 2.7.3 Internal overview mPCIe DOC_C-Series_Touch-PC_V1.1.docx Seite 18 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 19: Replace M.2 Flash Memory

    Gently push the module down and fix it on the board with the screw (M2) Important Note Only replace with module with correct pinout according to 2.4.10 on page 16 DOC_C-Series_Touch-PC_V1.1.docx Seite 19 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 20: Replace Cmos Battery

    Extract with tweezers and replace with same type (Littelfuse 452004.MRL) 2.7.8 Replace SODIMM Loosen the six screws on the back Tool: Hexagon socket screw driver number 2 Remove the cooling plate DOC_C-Series_Touch-PC_V1.1.docx Seite 20 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 21 Push the module down holding it on both edges until the locking secures the module firmly Important Note Only replace with module with correct specifications according to 2.4.10 on page 14 DOC_C-Series_Touch-PC_V1.1.docx Seite 21 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 22: Re-Assemble The Device (Backplate)

    Do not use a coarse scouring cloth, scouring powder or solvent. Cleaning should only be carried out when the device is switched off! Make sure the device has cooled down to room temperature DOC_C-Series_Touch-PC_V1.1.docx Seite 22 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 23: Spare Parts

    Flash module M.2 2242 Flash Memory xxGB KDxxGFy-240SM6 CMOS battery CR2032 3.0V 225mAh CPN/CR2032-CAB15A Thermal Gap Pad Gap Pad 25x33x1.016mm, 5W/mK CPN/SILICPAD5-25X33C Fuse 4A slow-blow Littelfuse 452004.MRL DOC_C-Series_Touch-PC_V1.1.docx Seite 23 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 24: Installation Description

    Required Cut out HBxxxPU8yyy-zZZZ Mounting Angle: Mounting Angle must be 90° Cooling Space: To ensure cooling leave enough free space around the product to enable a free air flow DOC_C-Series_Touch-PC_V1.1.docx Seite 24 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 25: Fig. 4 Screws To Hold The Mounting Frame

    Reattach the mounting frame and fix it into place by reattaching the screws highlighted in red. Required torque: 1.3Nm The product is now installed properly. Wall Projected capacitive touch panel Fig. 5 Fully installed C-Series Touch-PC DOC_C-Series_Touch-PC_V1.1.docx Seite 25 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 26: Installation And Cabling

    The AC/DC power supply must fulfil the requirements for EMI/RFI -certification. 3.2.3 Cabling the interfaces Use appropriate cabling for all interfaces. Shielded cabling is required to meet the EMI/EMC limits. DOC_C-Series_Touch-PC_V1.1.docx Seite 26 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 27: Grounding

    It is better to clamp the shields onto a grounded copper rail. Fig. 6 Additional grounding of the cable shields at the entry point of a cabinet DOC_C-Series_Touch-PC_V1.1.docx Seite 27 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 28: Cabling Of Communication Links

    It is better to clamp the shields onto a grounded copper rail. Fig. 7 Isolated communication link DOC_C-Series_Touch-PC_V1.1.docx Seite 28 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 29: Fig. 8 Non-Isolated Communication Link With Common Chassis Potential

    C-Series Touch-PC: user documentation DOC/ C-Series_Touch-PC; V1.1 Fig. 8 Non-isolated communication link with common chassis potential DOC_C-Series_Touch-PC_V1.1.docx Seite 29 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 30: Technical Data

    Depending on installed CPU and specific use case; see 4.4 Cold start-up: -20°C Do not connect to lines directly leaving a building without additional safety measures DOC_C-Series_Touch-PC_V1.1.docx Seite 30 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 31: Emi / Emc Specification

    To fullfill class A of EN55032 and EN55035 a CE-conformal AC/DC power supply must be used. Cable length between power supply and device is limited to 3m. DOC_C-Series_Touch-PC_V1.1.docx Seite 31 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 32: Mechanical Data

    Mechanical Data 4.3.1 TFT/HB101PU81xxx-C001y Ground fastener DOC_C-Series_Touch-PC_V1.1.docx Page 32 of 37 © 2019 Syslogic Datentechnik AG | All rights reserved...
  • Page 33: Use Cases

    Maximum ambient temperature is highly dependent on mounting, air flow and CPU/GPU load; with the Technologies the processor automatically reduces the internal CPU when the critical thermal trip points are reached to prevent damage. DOC_C-Series_Touch-PC_V1.1.docx Page 33 of 37 © 2019 Syslogic Datentechnik AG | All rights reserved...
  • Page 34: Firmware

    By default, the system does not contain any special API beside the installed BIOS. Please contact technical support for assistance. Supported Operating System Syslogic offers and supports Windows and Linux Debian operating systems. Please visit www.syslogic.com for the latest releases.
  • Page 35: Product Revision History

    Therefore, this information may be incompatible with the prototyping board hardware. Device Identification (see product label) BIOS Version Build Date Remarks TFT/HB101PU81xxx-C001y IBIOSAL053-A101_1 09.10.2018 Tab. 16 Firmware Revision State DOC_C-Series_Touch-PC_V1.1.docx Seite 35 von 37 © 2018 Syslogic Datentechnik AG | All rights reserved...
  • Page 36: Errata

    BIOS. It is important therefore that neither the application software nor the operating systems reprograms the processor chipset's configuration registers. Note that prototype board errata (boards with revision #0) are not listed here. Contact Syslogic technical support for prototype board information.
  • Page 37: Seite 2 Von

    RMA Service Syslogic offers a Return Material Authorization process to simplify handling of devices that needs to be returned to the manufacturer. Please follow the instructions on our web page: https://www.syslogic.com...

Table of Contents