VIGO VG06045 Series Installation Manual

Shower enclosure
Hide thumbs Also See for VG06045 Series:

Advertisement

Quick Links

VIGO INDUSTRIES INSTALLATION GUIDE FOR
SHOWER ENCLOSURE (MODEL VG06045)
!
SAFETY PRECAUTIONS
This Installation Guide uses the following symbols to indicate important information.
Always observe the instructions indicated by these symbols.
!
WARNING
Instructions that, if ignored, could result in death or serious personal injury caused by
incorrect handling or installation of the product. These instructions must be observed for
safe installation.
IMPORTANT
Maintenance and other important non-personal injury and non-material damage instructions
or statements that should be observed.
It is highly advised to dry fit the unit prior to any installation.
*VIGO reserves the right to modify/update all hardware and glass components based on
bettering the product for the end user's experience. If you have any questions contact VIGO
Tech Support at 1-866-591-7792.
REV 1 - 4/9/18
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VG06045 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for VIGO VG06045 Series

  • Page 1 It is highly advised to dry fit the unit prior to any installation. *VIGO reserves the right to modify/update all hardware and glass components based on bettering the product for the end user's experience. If you have any questions contact VIGO Tech Support at 1-866-591-7792.
  • Page 2 MODEL VG06045 RYLAND INSTALLATION INSTRUCTIONS FOR STANDING SHOWER CABIN PLEASE READ INSTRUCTIONS BEFORE PROCEEDING Parts List Top Wall Mount Bracket Assembly (2pc) 1A. Bottom Wall Mount Bracket Assembly (2pc) Top Roller Guide (1pc) Rollers (2pc) Fixed Panel (1pc) Door Panel (1pc) Handle Assembly (1pc) Fixed Panel Holder (1pc) Top Structural Rail (1pc)
  • Page 3 VG06045XX6473 A & B DIMENSIONS WERE MEASURED AFTER SHOWER ENCLOSURE WAS COMPLETELY INSTALLED Product lines may change, contact your Vigo representative at 1-866-591-7792 or visit our website at www.vigoindustries.com for the most up to date product line information. MODEL VG06045...
  • Page 4: Before Starting

    Compare items on your invoice with what you have received. Carefully review the Parts List on page 2. If any items are missing, please call Vigo Industries at 1-866-591-7792. Please check our website at www.vigoindustries.com for additional information or instructional videos.
  • Page 5 IMPORTANT Verify that the overall size of the shower door opening is appropriate for the shower enclosure. Due to individual site variations, exact guidelines for every situation cannot be supplied. The recommended framing and dimensional requirements are shown for a typical application and may vary depending on the site requirements.
  • Page 6: Installation Steps

    INSTALLATION STEPS INSTALLING THE BOTTOM STRUCTURAL RAIL Key Note: There is an arrow marker on the bottom structural rail (#9). This is the installation point of the fixed panel holder (#7). See the chart to determine the distance from the center of hole to the finished wall.
  • Page 7 Position the structural rail correctly using a level. Mark the location of the wall mount brackets (#1A) on the wall. Make sure that the allen screws are facing towards the inside of the shower stall. Mark the location of the fixed panel holder (#7) on the floor using the arrow marker on the structural rail as a guide.
  • Page 8 Prior to installing the bottom structural rail (#9), screw the fixed panel holder (#7) to the floor with the 3/4" phillips screw (#14). It is highly recommended to dry fit the fixed panel (#4) at this point. Review the location of the fixed panel holder (#7) and the notch FIXED PANEL (4) on the bottom of the fixed panel (#4) to...
  • Page 9 Install the hex screw covers (#17) to the bottom wall mount brackets (#1A). If this is not done now, the installation of the front fixed panel in the next step will make this impossible. INSTALLING THE FRONT FIXED PANEL Remove the fixed panel holder face plate/cap from the inside facing portion of FIXED PANEL HOLDER (7)
  • Page 10 Use the level to position the front fixed panel correctly. Make sure the seal strip (#10) is against the wall. Mark holes on the wall for the mounting screws. Make sure the cut out for the fixed panel holder on the fixed panel matches with the center point of the fixed panel holder (#7) the fixed panel (#4) and the bottom structural rail (#9)
  • Page 11 5. Screw the fixed panel to the wall with the with 1 5/8" screws (#13). Replace the fixed panel holder face plate/cap to the fixed panel holder by screwing the cap back on from the other side of the glass. VIEW FROM THE OUTSIDE FIXED PANEL (4) FIXED PANEL...
  • Page 12 INSTALLING THE TOP STRUCTURAL RAIL The top roller guide (#2) is already placed on the top structural rail (#8) for your convenience. Place the top wall mount brackets (#1) on both ends of the top structural rail (#8), if not already done. If the structural rail is too long, then cut it with the hacksaw until it fits the opening.
  • Page 13 emove the structural rail. Install the mounting clips by drilling holes at the center point of your markings and inserting plastic anchors (#16) inside them. Replace the mounting clips and screw them into the MOUNTING CLIP plastic anchors with the hex screws (#13). Not necessary if installing into studs.
  • Page 14: Installing The Door

    INSTALLING THE DOOR Remove the rollers (#3) from the box. Remove the cover. The three outside ROLLER COVER screws are what you will loosen to place the rollers on the door. The center screw is referred to as the roller height adjustment screw.
  • Page 15 MODEL SIZE RIGHT DOOR INSTALLATION LEFT DOOR INSTALLATION 48X74 3 3/8" 3 3/8" 3 3/8" 3 3/8" 4 1/8" 4 1/8" 14 9/16" 14 9/16" 3 3/4" 3 3/4" 50X74 3 3/8" 3 3/8" 3 3/8" 3 3/8" 4 1/8" 4 1/8"...
  • Page 16 Attach the seal strip (#10) to the door panel on the side that closes to the wall. Start at the bottom and work your way up, using the heel of your hand to firmly press the seal WALL strip onto the glass. SIDE The door seal strips must all meet each other properly to avoid any leakage.
  • Page 17 Position the door on top of the bottom structural rail (#9) making sure the rollers (#3) are straddling the rail. Slide the top roller guide (#2) along the fixed panel closer TOP ROLLER GUIDE (2) to the door so that the door panel slides into HEX SCREWS the opening.
  • Page 18: Installing The Handle

    INSTALLING THE WATER SEAL STRIP Attach the door seal strip (#19) to the door and to the fixed panel, respectively. Start at the bottom and work your way up, using the heel of your hand to firmly press the seal strip onto the glass.
  • Page 19: Installing Covers

    APPLYING THE SILICONE Apply clear silicone caulking to the inside between the wall and side seal strip. Apply clear silicone caulking to the inside between the floor and the fixed front panel. INSTALLING COVERS Install screw covers (#17) to the unit. If you haven't already done so, install the roller covers.
  • Page 20 In order to keep your shower enclosure in optimal working condition, Vigo recommends regularly inspecting your enclosure and tightening any hardware that may have loosened during use. This simple step will insure optimal results from your Vigo shower enclosure for many years to come.
  • Page 21 IMPORTANT ROLLER ADJUSTMENTS TO ACCOMMODATE OUT OF SQUARE OPENINGS NOTE: There is an adjustment on the roller to accommodate walls that are not 100% plumb. The bottom screw on the face of the roller adjusts the height of the ball bearing inside. Loosen this screw, adjust to desired closed door position and tighten in place.
  • Page 22 WALL WALL The roller height adjustment screw is in the normal position The roller height adjustment screw is in the normal position STRAIGHT WALLS ROLLER "A" ROLLER "B" WALL DIRECTION ROLLER HEIGHT ROLLER HEIGHT ADJUSTMENT SCREW ADJUSTMENT SCREW STRAIGHT WALL NORMAL NORMAL FIG.
  • Page 23 Subject to the Warranty Service provision below, any product reported to the authorized dealer or to VIGO as being defective within the warranty period will be repaired or replaced (with a product of equal value) at the option of VIGO. This warranty extends to the original owner or end-user and is not transferable to a subsequent owner.

Table of Contents