FEATURES AND SPECIFICATIONS

All Uni-ram Solvent Recyclers feature rapid-start direct electric heating of solvent (so there is no dia-
thermic oil to change) as well as high-effi ciency condensers, air cooled with a motor driven fan. All of the
Recyclers can be used with any Uni-ram Automatic Apray Gun Cleaner. The "E" models are designed to
be linked directly to a Uni-ram "E" series Automatic Spray Gun Cleaner or to an external container. The
direct connection creates a self-contained Recycling System allowing Timer-controlled Transfer In and
Out between the Solvent Recycler and the other component.
MODEL
VOLTAGE(V)
CURRENT USAGE (A)
RECOMMENDED CIRCUIT AMPS
EXPLOSION PROOF PLUG /
RECEPTACLE
TANK CAPACITY
CONSENSER AND FITTING
LID GASKET
SOLVENT TRANSFER SYSTEM
DIMENSIONS (WDH")
WEIGHT (LB/KG)
** ALSO AVAILABLE IN VITON OR TEFLON

Safety Features:

Certifi ed to UL standards U2208 and CSA standards C22.2 No. 30 and No. 88 by ETL. Approved
for use in non hazardous locations as well as approved for use in hazardous locations Class 1,
Division 1, Group D and Class 1, Division 2, Group D.
Explosion proof construction and intrinsically safe electric circuitry.
Computer controlled with many built-in safety programs including temperature control of all criti-
cal points including tank, condenser and fan motor. Power is cut when the temperature at any of
these points rises above a pre-set level. Operation also terminates when other abnormal conditions
exist (eg: boiling does not start on time or the distillation process takes too long).
Automatic pressure relief lid system prevents pressure in the Distillation Tank from exceeding 0.5
to 1.0 psi. (0.035 to 0.070 kg/cm2).
Self Diagnostic error messages are displayed on the Display Panel.
Dual lid cover system.
Compact, enclosed cabinet for safe storage of the Solvent Receiving Container inside the cabinet.
Operating Features:
Rapid-start due to direct electric heating of solvent, no diathermic oil to change.
Short cool-down time. High effi ciency condenser, air cooled with motor driven fan.
Warranty: 1 year on unit, 2 years on pump.
URS500
URS600
110/120
13.3
20
5-20P / 5-20R
6-20P / 6-20R
5 US GAL (20L)
5 US GAL (20L)
COPPER
NEOPRENE**
NEOPRENE**
NO
19 X 19 X 45
20 X 20 X 45
130/59
4
URS500EP2
220/240
110/120
6.7
13.3
15
20
5-20P / 5-20R
5 US GAL (20L)
COPPER
COPPER
NEOPRENE**
NO
YES
19 X 19 X 45
130/59
140/64
Revision 2019-07
URS600EP2
220/240
6.7
15
6-20P / 6-20R
5 US GAL (20L)
COPPER
NEOPRENE**
YES
20 X 20 X 45
140/64

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Urs600 seriesUrs500Urs600Urs500ep2Urs600ep

Table of Contents