MANUAL - SOLVENT RECYCLERS - URS500, 600, 500EP2, 600EP2
ERROR
Flashing LED
CODE
Lights
READY
READY
(L)
32
3 TIMES
2 TIMES
33
3 TIMES
3 TIMES
Description
(H)
Micro Controller has been reset
due to power interruption or drop
in voltage during the recycling
operation.
a) Recycling did not fi nish in 6
hours due to power interruption or
excessive debris in Liner Bag
b) Temperature Set Point is too
low for the solvent.
c) Boiling point of solvent is
above maximim set point.
Press "OFF" and then "ON" but-
tons to resume operation. Discon-
nect power at the source for about
30 seconds. Usually nothing is
wrong with the unit.
a) Clean Distillation Tank following
Operating Procedure 7, replace
Liner Bag, following Operating
Procedure 9,
b) increase Temperature Set Point
following Operating Procedure 4
and recycle with virgin solvent
c) Solvent cannot be recycled.
21
Revision 2019-07