To Change the Temperature Set Point:
Make sure the "HEAT" and "FAN" lights are off . Press and hold the "OFF" button while pressing the "ON"
button repeatedly to cycle through the 6 possible Set Points. If you go past the desired Set Point, continue
to press the "ON" button until you cycle back to the missed Set Point.
TEMPERATURE SET
POINTS
90°C (194°F)
115°C (239°F)
140°C (284°F)
165°C (329°F)
190°C (374°F)
200°C (392°F)
The Temperature Set Point is pre-set at the
factory to 200°C (392°F) - all 3 lights are on.
5) Start Recycling
Press "ON" button. Distillation starts, "HEAT" and "FAN" lights come on.
If you want to stop recycling press "OFF".
6) Finish Recycling
The clean recycled solvent is available for use when the heat lamp goes off . Recycling is complete and
the unit is ready for the next operation when "HEAT" and "FAN" lights are off . Temperature set point indi-
cators - READY (L) and /or READY(H) lights are on but not fl ashing.
7) Transfer Clean Solvent
a) For models without the Solvent Transfer System: remove the pail and replace with an empty one.
b) For models with the Solvent Transfer System: turn the Transfer Timer knob clockwise fully. The clean
solvent will fl ow out of the Solvent Receiving Pail into either a free-standing, external container or the
Clean Solvent Pail of a Spray Gun Cleaner. The transfer will stop whwn the timer runs out.
8) Remove Debris:
Remove the Retainer Ring.
Slowly pull the Liner Bag containing the debris out of the distillation tank in a way that the Liner Bag does
not break.
Dispose of the debris in accordance with local regulations.
NOTE: If the bag sticks to the bottom of the tank, turn the recycler on for 5 minutes to loosen the bag from
the bottom of the tank, then lift the bag out while the bag is warm.
9) Clean Distillation Tank and Lid Surface
Distillation Tank:
Wipe and dry tank with a cloth.
Remove any remaining debris from the Distillation Tank using if necessary, plastic or wooden tools. Do
not clean with abrasive or hard metal instruments that can damage the tank. The warranty does not cover
such damage.