Daikin FTKS L Series Engineering Data page 9

Split, cooling only/heat pump, r-410a, inverter
Table of Contents

Advertisement

ED041204
Indoor Unit
Model
Outdoor Unit
Capacity
Rated (Min. ~ Max.)
Moisture Removal
Running Current (Rated)
Power Consumption
Rated (Min. ~ Max.)
Power Factor
EER (Cooling)
Rated (Min. ~ Max.)
Liquid
Piping
Gas
Connections
Drain
Heat Insulation
Max. lnterunit Piping Length
Max. lnterunit Height Difference
Chargeless
Amount of Additional Charge of Refrigerant
Indoor Unit
Front Panel Colour
H
M
Airflow Rate
L
SL
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (H × W × D)
Packaged Dimensions (H × W × D)
Weight (Mass)
Gross Weight (Gross Mass)
Sound Pressure
H / M / L / SL
Level
Sound Power
H
Level
Outdoor Unit
Casing Colour
Type
Compressor
Model
Motor Output
Type
Refrigerant Oil
Charge
Type
Refrigerant
Charge
H
Airflow Rate
SL
Type
Fan
Motor Output
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Starting Current
Dimensions (H × W × D)
Packaged Dimensions (H × W × D)
Weight (Mass)
Gross Weight (Gross Mass)
Sound Pressure
H / SL
Level
Sound Power
H
Level
Drawing No.
Note:
Split Type Air Conditioners FTK(X)S-L Series
kW
Btu/h
11,900 (4,800 ~ 13,600)
kcal/h
L/h
A
4.4 - 4.2 - 4.0 / 4.4 - 4.2
W
%
94.0 - 94.2 - 94.8 / 94.0 - 94.2
W/W
mm
mm
mm
Both Liquid and Gas Pipes
m
m
m
g/m
m³/min
(cfm)
W
Steps
Right, Left, Horizontal, Downwards
Removable / Washable / Mildew Proof
A
0.12 - 0.12 - 0.11 / 0.12 - 0.12
W
%
98.5 - 94.2 - 98.5 / 98.5 - 94.2
Microcomputer Control
mm
mm
kg
kg
dB(A)
dB
Hermetically Sealed Swing Type
W
L
kg
m³/min
(cfm)
W
A
4.3 - 4.1 - 3.9 / 4.3 - 4.1
W
884 - 884 - 884 / 884 - 884
%
93.4 - 93.7 - 94.4 / 93.4 - 93.7
A
mm
mm
kg
kg
dB(A)
dB
The data are based on the conditions shown in the table below.
Cooling
Indoor ; 27°CDB / 19°CWB
Outdoor ; 35°CDB / 24°CWB
FTKS35LVMA
RKS35LVMA
3.5 (1.4 ~ 4.0)
3,010 (1,200 ~ 3,440)
1.9
910 (350 ~ 1,160)
3.85 (4.00 ~ 3.45)
φ 6.4
φ 9.5
φ 16.0
20
15
10
20
FTKS35LVMA
White
11.3 (399)
8.6 (304)
5.9 (208)
4.6 (162)
Cross Flow Fan
23
5 Steps, Quiet, Auto
26 - 26 - 26 / 26 - 26
295 × 800 × 215
274 × 870 × 366
10
13
42 / 34 / 26 / 23
58
RKS35LVMA
Ivory White
1YC23AEXD
600
FVC50K
0.375
R-410A
1.2
36.0 (1,271)
30.1 (1,063)
Propeller
33
4.4
550 × 765 × 285
589 × 882 × 363
34
38
49 / 44
63
3D075854
Piping Length
7.5 m
50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V
FTKS46LVMA
RKS46LVMA
4.6 (1.7 ~ 5.3)
15,700 (5,800 ~ 18,100)
3,960 (1,460 ~ 4,560)
2.9
5.8 - 5.5 - 5.3 / 5.8 - 5.5
1,250 (440 ~ 1,760)
98.0 - 98.8 - 98.3 / 98.0 - 98.8
3.68 (3.86 ~ 3.01)
φ 6.4
φ 12.7
φ 16.0
Both Liquid and Gas Pipes
30
20
10
20
FTKS46LVMA
White
12.2 (431)
10.6 (374)
9.0 (318)
7.9 (279)
Cross Flow Fan
23
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downwards
Removable / Washable / Mildew Proof
0.15 - 0.14 - 0.14 / 0.15 - 0.14
32 - 32 - 32 / 32 - 32
97.0 - 99.4 - 95.2 / 97.0 - 99.4
Microcomputer Control
295 × 800 × 215
274 × 870 × 366
10
13
44 / 40 / 35 / 32
60
RKS46LVMA
Ivory White
Hermetically Sealed Swing Type
2YC36BXD
1,100
FVC50K
0.650
R-410A
1.7
48.5 (1,713)
41.6 (1,469)
Propeller
53
5.6 - 5.4 - 5.2 / 5.6 - 5.4
1,218 - 1,218 - 1,218 / 1,218 - 1,218
98.9 - 98.1 - 97.6 / 98.9 - 98.1
5.8
735 × 825 × 300
792 × 960 × 390
46
52
47 / 44
61
3D075855
Specifications
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
7