Capacity Tables
FTKS35LVMA + RKS35LVMA (50 Hz, 220 - 240 V / 60 Hz, 220 - 230 V)
AFR
11.3
BF
0.14
INDOOR
EWB EDB
20
°C
°C
TC
SHC
14.0
20
3.44
2.67
0.70
16.0
22
3.60
2.63
0.71
18.0
25
3.75
2.77
0.71
19.0
27
3.83
2.94
0.71
22.0
30
4.06
2.84
0.72
24.0
32
4.21
2.77
0.72
Symbols:
AFR
: Airflow rate
BF
: Bypass factor
EWB
: Entering wet bulb temp.
EDB
: Entering dry bulb temp.
TC
: Total capacity
SHC
: Sensible heat capacity
PI
: Power input
FTKS46LVMA + RKS46LVMA (50 Hz, 220 - 240 V / 60 Hz, 220 - 230 V)
AFR
12.2
BF
0.14
INDOOR
EWB EDB
20
°C
°C
TC
SHC
14.0
20
4.10
3.08
0.91
16.0
22
4.73
3.23
0.97
18.0
25
4.93
3.38
0.98
19.0
27
5.03
3.55
0.98
22.0
30
5.34
3.42
0.99
24.0
32
5.54
3.33
0.99
Symbols:
AFR
: Airflow rate
BF
: Bypass factor
EWB
: Entering wet bulb temp.
EDB
: Entering dry bulb temp.
TC
: Total capacity
SHC
: Sensible heat capacity
PI
: Power input
34
OUTDOOR TEMPERATURE (°CDB)
25
PI
TC
SHC
PI
TC
3.28
2.60
0.77
3.13
3.44
2.56
0.77
3.28
3.59
2.70
0.78
3.44
3.67
2.87
0.78
3.51
3.90
2.78
0.79
3.75
4.06
2.72
0.79
3.90
(m³/min.)
(°C)
(°C)
(kW)
(kW)
(kW)
OUTDOOR TEMPERATURE (°CDB)
25
PI
TC
SHC
PI
TC
4.10
3.08
1.03
4.10
4.52
3.13
1.06
4.31
4.72
3.28
1.07
4.52
4.83
3.46
1.07
4.62
5.13
3.34
1.08
4.92
5.33
3.25
1.09
5.13
(m³/min.)
(°C)
(°C)
(kW)
(kW)
(kW)
30
32
SHC
PI
TC
SHC
2.52
0.84
3.19
2.55
2.49
0.84
3.36
2.52
2.64
0.85
3.52
2.67
2.81
0.85
3.60
2.84
2.73
0.85
3.84
2.76
2.67
0.86
4.00
2.70
Note:
1.
shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in the
above tables. (Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 7.5 m
Level difference : 0 m
30
32
SHC
PI
TC
SHC
3.08
1.15
4.10
3.08
3.04
1.16
4.41
3.08
3.19
1.16
4.62
3.24
3.37
1.16
4.73
3.42
3.26
1.17
5.05
3.31
3.18
1.18
5.26
3.23
Note:
1.
shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in the
above tables. (Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 7.5 m
Level difference : 0 m
Split Type Air Conditioners FTK(X)S-L Series
35
PI
TC
SHC
PI
TC
0.86
3.10
2.51
0.90
2.93
0.86
3.26
2.47
0.90
3.10
0.87
3.42
2.63
0.91
3.26
0.87
3.50
2.80
0.91
3.34
0.88
3.74
2.73
0.92
3.58
0.88
3.90
2.67
0.92
3.74
35
PI
TC
SHC
PI
TC
1.17
4.07
3.06
1.24
3.86
1.19
4.28
3.02
1.24
4.07
1.19
4.49
3.18
1.25
4.28
1.19
4.60
3.37
1.25
4.39
1.20
4.92
3.26
1.26
4.70
1.21
5.13
3.18
1.26
4.92
ED041204
40
SHC
PI
2.43
0.97
2.40
0.97
2.56
0.98
2.74
0.98
2.67
0.98
2.62
0.99
3D075532
40
SHC
PI
2.95
1.33
2.92
1.33
3.09
1.34
3.28
1.34
3.18
1.35
3.11
1.36
3D075506

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents