Daikin FTKS L Series Engineering Data page 16

Split, cooling only/heat pump, r-410a, inverter
Table of Contents

Advertisement

Specifications
Indoor Unit
Model
Outdoor Unit
Capacity
Rated (Min. ~ Max.)
Moisture Removal
Running Current (Rated)
Power Consumption
Rated (Min. ~ Max.)
Power Factor
EER (Cooling) / COP (Heating)
Rated (Min. ~ Max.)
Liquid
Piping
Gas
Connections
Drain
Heat Insulation
Max. Interunit Piping Length
Max. Interunit Height Difference
Chargeless
Amount of Additional Charge of Refrigerant
Indoor Unit
Front Panel Colour
H
M
Airflow Rate
L
SL
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (H × W × D)
Packaged Dimensions (H × W × D)
Weight (Mass)
Gross Weight (Gross Mass)
Sound Pressure
H / M / L / SL
Level
Sound Power
H
Level
Outdoor Unit
Casing Colour
Type
Compressor
Model
Motor Output
Type
Refrigerant Oil
Charge
Type
Refrigerant
Charge
H
Airflow Rate
SL
Type
Fan
Motor Output
Running Current (Rated)
Power Consumption (Rated)
Power Factor (Rated)
Starting Current
Dimensions (H × W × D)
Packaged Dimensions (H × W × D)
Weight (Mass)
Gross Weight (Gross Mass)
Sound Pressure
H / SL
Level
Sound Power
H
Level
Drawing No.
Note:
Outdoor ; 35°CDB / 24°CWB
14
kW
Btu/h
32,000 (10,200 ~ 38,200)
kcal/h
L/h
A
13.3 - 12.7 - 12.2 / 13.3 - 12.7
W
%
98.4 - 98.6 - 98.4 / 98.4 - 98.6
W/W
mm
mm
mm
m
m
m
g/m
m³/min
(cfm)
W
Steps
A
0.57 - 0.55 - 0.53 / 0.57 - 0.55
W
%
56.6 - 56.1 - 55.8 / 56.6 - 56.1
mm
mm
kg
kg
dB(A)
dB
W
L
kg
m³/min
(cfm)
W
A
13.0 - 12.4 - 11.9 / 13.0 - 12.4
W
2,809 - 2,809 - 2,809 / 2,809 - 2,809
%
98.2 - 98.5 - 98.4 / 98.2 - 98.5
A
mm
mm
kg
kg
dB(A)
dB
The data are based on the conditions shown in the table below.
Cooling
Indoor ; 27°CDB / 19°CWB
Outdoor ; 7°CDB / 6°CWB
FTXS95LVMA
RXS95LVMA
Cooling
9.4 (3.0 ~ 11.2)
8,080 (2,580 ~ 9,630)
6.3
2,880 (620 ~ 4,320)
3.26 (4.84 ~ 2.59)
Both Liquid and Gas Pipes
FTXS95LVMA
22.7 (802)
19.0 (671)
15.5 (547)
13.2 (466)
Cross Flow Fan
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downwards
Removable / Washable / Mildew Proof
71 - 71 - 71 / 71 - 71
Microcomputer Control
340 × 1,200 × 240
325 × 1,310 × 429
51 / 47 / 42 / 38
67
RXS95LVMA
Ivory White
Hermetically Sealed Swing Type
2YC63FXD
FVC50K
79.4 (2,804)
64.8 (2,288)
Propeller
990 × 940 × 320
1,114 × 1,003 × 425
54 / 50
68
3D075825A
Heating
Piping Length
Indoor ; 20°CDB
50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V
Heating
10.5 (3.0 ~ 11.7)
35,800 (10,200 ~ 39,900)
9,030 (2,580 ~ 10,060)
14.8 - 14.1 - 13.5 / 14.8 - 14.1
3,220 (620 ~ 4,360)
98.9 - 99.3 - 99.4 / 98.9 - 99.3
3.26 (4.84 ~ 2.68)
φ 9.5
φ 15.9
φ 16.0
30
20
10
50
White
24.9 (879)
20.1 (710)
15.7 (554)
14.1 (498)
64
0.55 - 0.53 - 0.51 / 0.55 - 0.53
68 - 68 - 68 / 68 - 68
56.2 - 55.8 - 55.6 / 56.2 - 55.8
18
25
50 / 44 / 38 / 35
66
2,030
0.750
R-410A
3.2
73.6 (2,599)
64.8 (2,288)
200
14.5 - 13.8 - 13.2 / 14.5 - 13.8
3,152 - 3,152 - 3,152 / 3,152 - 3,152
98.8 - 99.3 - 99.5 / 98.8 - 99.3
14.8
82
94
55 / 51
69
7.5 m
Split Type Air Conditioners FTK(X)S-L Series
ED041204
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3