Ezy-Wash
®
PRODUCT CODE:
- TF81HJS
- TF81HJP
SPECIFICATIONS
 Galvin Specialised recommends the installation of strainers and pressure reducing valves prior to installing
the pre-rinse unit to ensure clean consistent water supply. Debris or poor water quality could cause the
trigger to seize or fail to seal.
This pre-rinse unit has a 6 star WELS rating, the Pot Filler attachments are 0 star to allow fast pot filling.
TECHNICAL DATA
Inlet
Outlet
Headworks
Working Pressure Range (kPa)
Working Temperature Range (°C)
Nominal Flow Rate (LPM)
Finish
NOTE: Galvin Specialised continually strives to improve their products. Specifications may change without
notice. Higher temperature or pressures could result in premature failure and void the manufacturer's warranty.
TOOLS REQUIRED
 Adjustable spanner
 Hex key
Power drill
Pre-Rinse Tapware
Version 2, 3 August 2017, Page 1 of 5
TF81HJS
½" BSP – Male
TF81HJS
Trigger Spray
TF81HJP
Trigger Spray & Pot Filler
TF81HJS
Jumper Valve
TF81HJP
Jumper Valve
Min
100
Max
500
Min
5
Max
65
TF81HJS
3.5
TF81HJP
15
Chrome
TF81HJP

Advertisement

loading

Summary of Contents for Galvin Engineering Ezy-Wash TF81HJS

  • Page 1 Version 1, 3 August 2017, Page 1 of 5 Version 2, 3 August 2017, Page 1 of 5 Ezy-Wash ® Pre-Rinse Tapware PRODUCT CODE: - TF81HJS - TF81HJP TF81HJS TF81HJP SPECIFICATIONS  Galvin Specialised recommends the installation of strainers and pressure reducing valves prior to installing the pre-rinse unit to ensure clean consistent water supply.
  • Page 2: Pre-Installation

    Version 1, 3 August 2017, Page 2 of 5 Version 2, 3 August 2017, Page 2 of 5 PRE-INSTALLATION Body:  If the mounting hole does not already exist, mark out and drill the hole in the bench, as shown. ...
  • Page 3: Installation

    Version 1, 3 August 2017, Page 3 of 5 Version 2, 3 August 2017, Page 3 of 5 INSTALLATION INSTALLATION COMPLIANCE: Galvin Specialised products must be installed in accordance with these installation instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical supply conditions must also comply to the applicable national and/or state standards.
  • Page 4 Version 1, 3 August 2017, Page 4 of 5 Version 2, 3 August 2017, Page 4 of 5 TF80H-S TF80HJP TF81HJS TF81HJP 5. Fit pre-rinse riser assembly 6. Secure pre-rinse assembly 1. Fit compression nut to support rod, followed  Secure pre-rinse assembly with the supplied by the compression cone and locate the flanged back nut;...
  • Page 5: Warranty

    WARRANTY The warranty set forth herein is given expressly and is the only warranty given by the Galvin Engineering Pty Ltd. With respect to the product, Galvin Engineering Pty Ltd makes no other warranties, express or implied.

This manual is also suitable for:

Ezy-wash tf81hjp