Code
Contents
8930
Center-folding unit backup
error
Read and write data does not
match 3 times in succession.
Service Manual
Causes
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
CF main PWB (YC7) and DF main PWB
(YC9)
Improper installa-
Check the installation of the EEPROM and
tion EEPROM.
remedy if necessary.
Defective CF main
Replace the CF main PWB and check for
PWB.
correct operation.
1-4-25
3NB/3ND/3N0/3NK
Check procedures/
corrective measures
Y113480-7

Hide quick links: