Vermont Castings 2767/FK26 Installation Instructions Manual page 9

Fan kit for radiance, stardance, dutchwest & oxford gas heaters and defiant nc, dutchwest nc and encore nc wood stoves
Table of Contents

Advertisement

6. Position the fan assembly so the ducts slide between the
inner and outer shroud. The inner shroud should engage
with the two (2) slots in the ends of the bracket so that
bracket and shroud are interlocked. (Figure 25) Secure
the bracket with the four (4) sheet metal screws provided
in the finish bag.
Outer
Shroud
Figure 25 - Position the fan to engage the inner shroud with the fan
bracket slots and secure with sheet metal screws.
ST194
7. Route the rheostat wire assembly to the right between the
attach fan to shroud
inner and outer shroud. Run the wire through the slots at
11/99
the bottom right corner of the inner shroud. Some models
have the extension wire assembly attached to the inner
shroud.
8. Refasten the outer shroud to the inner duct assembly.
9. Install the snapstat by loosening the front screw on the
inner side of the duct. (Figure 26) Slide the snapstat
under the head of the screw and tighten. Connect the
leads to the snapstat. Make sure the snapstat assembly
is mounted straight front to back.
Left Air Duct
Figure 26 - Install the snapstat and connect to the extension wire
terminals. View is with top removed, however, access is available
through the rear when installing fan before gas line connection.
ST195
attach snapstat
10. Slide shroud assembly over the sides and fasten the four
11/99
(4) screws loosened earlier.
11. The rheostat control switch attaches to the left side of
the valve bracket at the front of the stove. (Figure 27)
Remove retaining nut from shaft of rheostat. (if
preinstalled)
Insert the rheostat through the hole in the back of the
left side of the valve bracket, aligning the locator pin
with the smaller hole in that bracket.
Thread the retaining nut onto the shaft of the rheostat,
tightening with a wrench. Do not overtighten.
9
Slot
Inner Shroud
Slot
Snapstat
Attach the control knob to the rheostat shaft.
Use the wire tie to secure the fan and rheostat wire
harnesses together.
Retaining Nut
Control Knob
Figure 27 - Attach rheostat to left side of valve.
13. Plug the power cord into a standard grounded 110 volt
household outlet. If the fan control knob is not turned
to the OFF position, the fan will turn on when the
temperature at the snapstat reaches approximately
109°F.
ST347a
JUV
FK28
rheostat install
9/21/00
2003135