Figure 31 - Attach fan assembly to fan bracket.
ST669
Outer
Shroud

RUVSOD

attach fan to bracket
7/01
Figure 32 - Position the fan to engage the inner shroud with the fan
bracket slots and secure with sheet metal screws.
7. Plug the power cord into a standard grounded 110 volt
ST194
attach fan to shroud
household outlet.
11/99
Left Air Duct
Figure 33 - Install snapstat to left air duct.
ST195
attach snapstat
11/99
11
Snapstat
Wire
Rheostat Wire
Fan Bracket
Finger Guard
Slot
Inner Shroud
Slot
Snapstat
B
A
RUVSOD
1. Loosen the four (4) phillips head screws which secure the
rear shroud to the stove sides. (Figure 34)
2. Carefully pull the shroud assembly away from the rear of
the stove.
3. With the rear shroud assembly in the upright position, set
the bottom of the shroud on a padded surface to prevent
scratching. Unfasten the four (4) phillips head screws
which attach the outer shroud to the inner duct assembly.
NOTE: If you are installing the fan kit after the stove is
in its final location, follow same steps, except disengage
only the right side of the outer shroud.
Rear Shroud
Assembly
Figure 34 - Loosen four (4) phillips screws holding the rear shroud
assembly and remove. Remove four phillips screws holding rear
shroud to inner duct assembly. Remove rear shroud.
4. Attach the fan assembly to the fan bracket provided in
the log box that came with the stove. Use the #10 sheet
metal screws provided with fan kit. Do not remove finger
guard screws. (Figure 35)
Figure 35 - Attach fan assembly to fan bracket.
ST669
RUVSOD
attach fan to bracket
7/01
ST189
fan remove shroud
radiance
11/99
Snapstat
Wire
Rheostat
Wire
Fan
Bracket
Finger Guard
2003135