Outer
Shroud
Figure 62 - Position the fan to engage the inner shroud with the fan
bracket slots and secure with sheet metal screws.
ST194
attach fan to shroud
11/99
Left Air Duct
Figure 63 - Install the snapstat and connect the extension wire
terminals. View is with top removed, however, access is available
through the rear when installing fan before gas line connection.
7. Install the snapstat by loosening the front screw on the
inner side of the duct. (Figure 63) Slide the snapstat under
the head of the screw and tighten. Connect the leads to
the snapstat. Make sure the snapstat assembly is mounted
straight front to back.
8. After sliding the firebox in place, the rheostat control switch
attaches to the left side of the valve bracket at the front
ST671
of the stove. (Figure 64)
attach snapstat
Remove retaining nut from shaft of rheostat. (if
preinstalled)
Insert the rheostat through the hole in the back of the
left side of the valve bracket, aligning the locator pin
with the smaller hole in that bracket.
Thread the retaining nut onto the shaft of the rheostat,
tightening with a wrench. Do not overtighten.
Attach the control knob to the rheostat shaft.
Use the wire tie to secure the fan and rheostat wire
harnesses together.
9. Plug the power cord into a standard grounded 110 volt
household outlet. If the fan control knob is not turned to
the OFF position, the fan will turn on when the temperature
at the snapstat reaches approximately 109°F.
19
Slot
Inner Shroud
Slot
Snapstat
Rheostat
Retaining nut
Rheostat Knob
Figure 64 - Attach fan rheostat.
Rheostat
ST347a
JUV
FK28
rheostat install
9/21/00