3.7:
Perform an ON/OFF test by pushing and releasing the 'On' button. The beacon
should flash at least once and a beep should be heard with each flash. Switch off the
beacon by pushing and holding the 'Off' button – the beacon should switch off after
approximately 3 seconds.
NOTE: Do not allow beacon to operate for longer than 15 seconds.
4. LEAK TEST
4.1 Overview:
 At this stage a gross leak test unit plunged into warm water is recommended.
 Note: The leak test must be completed before the full function test.
 Use hot water at 60°C ±5°C (140°F ± 9°F)
 Cooler water will not raise the air pressure enough.
 Hotter Water may damage the unit.
4.2 Instructions:
a) It is best to remove lanyard (if fitted).
b) Remove the Red cap and deploy the antenna (the unit will then turn on so
turn it off before proceeding)
c) Immerse the unit in the hot water.
d) Dislodge ALL trapped air from the screw holes etc.
e) During the next 5 minutes, rotate the unit and check for any escaping
bubbles
NB. If there is any sign of water ingress (bubbles are seen escaping), quickly
remove the unit from the water
f) If no bubbles are observed, remove unit from water and thoroughly dry
g) Refit removed parts.
Any escape of bubbles must be corrected by Disassembly, rebuild and re-test. A new sealing
kit will be required.
Orolia Ltd, Silver Point, Airport Service Rd, Portsmouth, Hants, PO3 5PB, United Kingdom
Tel: +44 (0) 23 9262 3900 Fax: +44 (0) 23 9262 3998 Email:
service.uk@mcmurdogroup.com