Possible causes of faults

Error
Possible cause
code
10
Feeder does not supply enough of
pellets.
Empty pellet container.
Faulty ignition fuse.
Faulty ignition spiral.
Photocell needs to be cleaned.
11
Feeder does not supply enough of
pellets.
Empty pellet container.
Faulty ignition fuse.
Faulty ignition spiral.
Photocell needs to be cleaned..
12
Short circuit or other fault of
photocell.
13
Too high temperature in boiler
room.
14
Faulty sensor of thermostat
15
Faulty sensor of thermostat
16
Faulty circuit board
18
Ventilator runs, while the burner
is in pause regime.
19
Ventilator does not run, when it
should.
20
Ventilator runs too slowly
21
First ignition trial failed
22
Pellet feeder missing
23
Incorrect pellet feeding
24
Incorrect amount of pellets
feeded.
Faulty photocell
25
Cleaning does not work
26
Cleaning is slow
Actions to correction
Set pellet ration.
Fill the container.
Replace fuse. (6.3A).
Replace spiral. (48 Ώ +/- 5%).
Clean photocell.
Set pellet ration.
Fill the container.
Replace fuse. (6.3A).
Replace spiral. (48 Ώ +/- 5%).
Clean photocell.
Replace photocell.
Prevent from heat leakage.
Replace sensor.
Replace sensor.
Replace circuit board.
Replace circuit board.
Change ventilator fuse (800mA); check
connections; replace ventilator
Clean ventilator; replace ventilator
Set pellet ration.
Connect pellet feeder
Set pellet ration.
Set pellet ration.
Replace photocell.
Check connection between circuit board of
scraper and main circuit board.
Clean grate