PELLET BURNER
PELH30A
MANUAL FOR ATTENDANCE
Manual for installation and start-up
EN - 01.07.2010

Advertisement

Table of Contents
loading

Summary of Contents for ATTACK PELH30A

  • Page 1 Appendix Nr.1 PELLET BURNER PELH30A MANUAL FOR ATTENDANCE Manual for installation and start-up EN - 01.07.2010...
  • Page 2: Table Of Contents

    Content 2 Important information 3 Technical description 4 Dimensions / Range of delivery 5 Technical data 6 Description of function 7 How to use pellet burner 8 Menu buttons and their function 9 Texts on display 10 Texts of menu 11 Production settings 12 How to change production settings 13 How to install pellet burner...
  • Page 3: Important Information

    Device for pellet burning, PELH30A has to be connected to boiler that is suitable for heating with solid fuel. Suitable boiler is ATTACK PELLET 30, resp. 30A. Boiler door and connections between boiler and chimney have to be airtight.
  • Page 4: Technical Description

    Technical description PELH30A is designed on basis of fuel feeding by principle of falling, when the pellet fall by self-force from pellet feeder through inlet hose and inlet tube on the grate, where the combustion runs. PELH30A has electrical ignition that automatically ignites pellets fallen on the grate.
  • Page 5: Dimensions / Range Of Delivery

    Dimensions / range of delivery PELH30A is delivered in paper box filled with polysthyrene to improve stability. If the box is damaged, check burner for possible damage by transport. Reclamation of damage by transport has to be recorded by spediteur.
  • Page 6: Technical Data

    Technical data Model PELH30A Fuel Wood pellets, 6-10 mm Regime 8 – 12 kW; 14 – 30 kW Scale of output 8 - 30 kW, graduated by 2 kW For boilers with heat chamber up to 3 m² Weight 22 kg...
  • Page 7: Description Of Function

    Description of function NOTE: PELH30A works only by usage of boiler thermostat or built-in digital thermostat, resp. with additional room thermostat. In both cases the burner has to be connected through fuse against boiler overheating. Normal start-up When the thermostat gives instruction to burner, ventilator starts and fotocell controls fire.
  • Page 8: How To Use Pellet Burner

    Pellet burner must not be started, until it is safely approved that smoke can freely go through boiler and chimney into the enviroment air. Pellets are feeded into PELH30A from external feeder connected to pellet container. For better function and the most balanced feeding, the feeder should be leant under angle of 45°.
  • Page 9 Values that can be set by user are given in the following schedule: MENU Explanation EFFECT ADJ. Required output degree (1, 2 or 3) PELLET-TRIM Setting of feeded pellet ration Record of faults for control purposes FINAL COMBUST. Instruction to burner for burn-out MENU/ ADVANCED Access into service menu via code...
  • Page 10 Indications on display Emergency regime Nothing in the burner is started, burner waits for start signal PAUS. from thermostat. FC: 0 % Thermostat starts. Step 1 Test blow-through Fan starts to operate and when the photocell recognizes TEST BLOWING value under 5%, program continues. FC: ? % Step 2 Fuel ration for heating up Fuel ration for heating up is feeded into burner and program...
  • Page 11 Menu Indications Burner is in standby regime. PAUS. FC: 0 % Press the”M” button. Here you can change burner output. Level 1 = 8 (14)kW, 2 EFFECT LEVEL = 10 (22)kW, 3 = 12 (30)kW. ENTER EXIT Range and Levels of Output are adjustable in advanced menu.
  • Page 12: Production Settings

    Production settings Before delivery was burner set in the following way: Generally available menu: Menu Settings Option Adjustable Effect level 1 = 14 kW 1, 2, 3 8-30 kW Pellet-trim 95 % 50-200 % 50 – 200 % Final combustion 90 sec.
  • Page 13 Menu/ Settting See Extended Menu / Log Saves error codes See Extended * ) Languages: Slovak, English, German, Italian, French, Polish.
  • Page 14: How To Change Production Settings

    How to change production settings To change settings, select required menu/parameters. By pressing of the „+“ button, change actual values. O: ...shows actual temperature, N:...can be changed to new value. It is possible to increase vaues by „+“ and decrease them by „-“. By the „M“ button is change confirmed and saved.
  • Page 15: How To Install Pellet Burner

    How to install pellet burner Pellet burner PELH30A can be installed only by qualified, specifically skillfull personnel. Burner door are from production mounted to boiler. Put the burner on door screws and fasten it by nuts (B). Connect inlet pipe to pellet feeder under the required angle.
  • Page 16: Burner Start

    Burner start By turning the boiler´s main switch on is the burner automatically turned into emergency regime. Burner is put into operation by turning the burner´s switch on and by turning boiler´s thermostat into position adequate to required boiler temperature. Following demand for heat supply is the burner ignited and burns pellets, until the thermostat gives instruction to stop.
  • Page 17: Cleaning And Maintenance

    Cleaning and maintenance It is necessary to clean the burner after every consumption of 2000kg of pellets. It is based on presumption, that boiler accepts appropriate amount of ash and quality pellets are being burned. Moreover, it is recommended to sweep exchanger´s parts of the boiler at least twice a month.
  • Page 18 Trobleshooting Burner turned off. Check, which alarm was indicated on display. If display is black and without text, check thermal fuse of the boiler. If there is no error, probably is only the burner´s thermal fuse turned off. To start again, turn energy supply into burner off, remove cover and press small button between overheating fuse connections.
  • Page 19: Possible Causes Of Faults

    Possible causes of faults Error Possible cause Actions to correction code Feeder does not supply enough of Set pellet ration. pellets. Empty pellet container. Fill the container. Faulty ignition fuse. Replace fuse. (6.3A). Replace spiral. (48 Ώ +/- 5%). Faulty ignition spiral. Photocell needs to be cleaned.
  • Page 20: Decomposed View

    Decomposed view...
  • Page 21 23. Photocell 24. End-switch 25. Control panel 26. Grate panel 27. Self-adhesive control panel 28. Display panel 29. Grate gear Socket 31. Connector 32. Emergency thermostat with reset 33. Burner cabling 34. Silicon cuff 35. Cable lead-in 36. Logo „ATTACK“...
  • Page 22 El. scheme of connection, burner PELH30A...
  • Page 23: Endings And Connections, Fuses

    Endings and connections, fuses 1. 230 VAC – Phase 2. 230 VAC – Directly earthed conductor 3. 230 VAC – Phase of thermostat 4. Ventilator – Directly earthed conductor 5. Ventilator – Phase 6. Feeder – Directly earthed conductor 7. Feeder – Phase 8.
  • Page 24: Accessories

    Accessories Name Number Ashpan Pellet container, 300l PEL9600 Pellet feeder, 1.5 m long Pellet feeder, 2.5 m long Pellet feeder, 5 m long...
  • Page 25: Contact Person And Electrotechnician

    Contact person and electrotechnician Date of installation Installed (by): Address-street ZIP Code, City Telephone Cell phone Service record Servised/ Flue gas Date CO ppm Service performed by: Checked temperature...
  • Page 26 Advanced menu Following data/parameters are adjustable only by qualified person. All points of advanced menu are available by pressing “M”. actual setting is permanently displayed in the left bottom corner under „O:“ (time/value), whereas new value is displayed in the right bottom corner under „N“: (time/value). To increase and decrease time or values, press buttons „+“...
  • Page 27 Setting of time of test blow-through Time of test blow-through defines time, within which will TEST BLOWING be boiler and chimney ventilated before beginning of ENTER < > EXIT combustion (10-100 seconds). For boilers, at which there is tough to achieve their draught, it is recommended to increase time of test blow-through, Pre-setting from production is for 15sec.
  • Page 28 Setting of photocell sensibility: Here you can set photocell sensibility, i.e. light value in PHOTOSENSOR (%), to which should system react as to fire. It should not ENTER < > EXIT be necessary to set the light sensibility, if correct photocell is installed.
  • Page 29 OPERATION TIME Here you can see, how long the pellet feeder worked. You OF FEEDER. can use it to calculate energy consumption, etc. ENTER < > EXIT Test: Use by troubleshooting. Here you can manually or MENU/TEST automatically control components. ENTER <...
  • Page 30 Record about installation for warranty claim Date of installation: 20…..-……-…... Installed in :……..……..………………… Telephone:……………………… Street:…………………………………..Fax:…………………………. ZIP Code and City: ………………….Mobil:……..………….. …………………………………………… Installed on boiler: Trademark:............ Model:………………………. Pellet burner:……………………………... Serial number:……………….. Pellet feeder: Trademark:……………………………….. Length:……………………….. Serial number:……………………………… Settings of pellet burner: Menu Production Options of...
  • Page 31 Date of installation: 20…..-……-…... Installed in :……..……..………………… Telephone:……………………… Street:…………………………………..Fax:…………………………. ZIP Code and City: ………………….Mobil:……..………….. …………………………………………… Installed on boiler: Trademark:............ Model:………………………. Pellet burner:……………………………... Serial number:……………….. Pellet feeder: Trademark:……………………………….. Length:……………………….. Serial number:……………………………… Settings of pellet burner: Menu Production Options of Set to settings settings Output level...
  • Page 32 ATTACK, s.r.o. producer rese rves the right to change technical parameters and dimensions of boilers without previous warning. Der Herstel ler ATTACK, s.r.o. behä lt sich das Re ch t der technischen Veräderun gen an Produ kten ohne eine vorige Warnung.