3. Summary Table Performance characteristics Indoor Unit Model Code Max. 20,000 High AC018MNADCH/AA 23.81 Std. 18,000 Mid. Min. 4,000 Max. 27,000 High AC024MNADCH/AA 32.19 Std. 24,000 Mid. Min. 7,000 Max. 37,000 High AC030MNTDCH/AA 40.57 Std. 30,000 Mid. Min. 9,000 Max. 38,000 High AC036MNTDCH/AA...
6. Dimensional Drawing Indoor Unit AC018MNADCH/AA Unit: mm (inch) Name Liquid pipe connection 6.35 (1/4") Gas pipe connection 12.7 (1/2") Drain pipe connection ID 18 HOSE Power supply & Communication wiring conduit...
Page 16
6. Dimensional Drawing Indoor Unit AC030MNTDCH/AA, AC036MNTDCH/AA Unit: mm (inch) 1280 (50-3/8) (9-15/16) Knockout hole for Knockout hole for left piping right piping 1530 (60-1/4) (14-5/16) (6-1/8) (2-9/16) (2-9/16) 64 (2-9/16) Wall hole for right rear piping (4-15/16) Wall hole for right rear piping Name Liquid pipe connection...
Page 17
6. Dimensional Drawing Outdoor unit AC018MXSCCC/AA Unit: mm (inch) Name Refrigerant liquid pipe Refrigerant gas pipe Drain Hole...
Page 18
6. Dimensional Drawing Outdoor unit AC024MXSCCC/AA Unit: mm (inch) Name Refrigerant liquid pipe Refrigerant gas pipe Drain Hole...
Page 19
6. Dimensional Drawing Outdoor unit AC030MXSCCC/AA, AC036MXSCCC/AA Unit: mm (inch) Name Refrigerant liquid pipe Refrigerant gas pipe Communication wiring conduit Drain Hole Connect with the provided drain plug...
7. Center of Gravity Indoor Unit Unit: mm (inch) AC018MNADCH/AA AC024MNADCH/AA Unit: mm (inch) AC030MNTDCH/AA 1280 (50-3/8) 412 (16-1/4) 207 (8-1/8) 345 (13-9/16) 253 (9-15/16) 111 (4-3/8) 207 (8-1/8) AC036MNTDCH/AA...
Page 21
7. Center of Gravity Outdoor Unit Unit: mm (inch) Hold location of foundation bolt Hold location of foundation bolt AC018MXSCCC/AA AC024MXSCCC/AA AC030MXSCCC/AA AC036MXSCCC/AA...
10. Temperature and air flow distribution AC018MNADCHAA 1) Cooling air velocity distribution 2) Cooling Temperature distribution 3) Heating air velocity distribution 4) Heating Temperature distribution...
Page 28
10. Temperature and air flow distribution AC024MNADCHAA 1) Cooling air velocity distribution 2) Cooling Temperature distribution 3) Heating air velocity distribution 4) Heating Temperature distribution...
Page 29
10. Temperature and air flow distribution AC030MNTDCHAA 1) Cooling air velocity distribution 2) Cooling Temperature distribution 3) Heating air velocity distribution 4) Heating Temperature distribution...
Page 30
10. Temperature and air flow distribution AC036MNTDCHAA 1) Cooling air velocity distribution 2) Cooling Temperature distribution 3) Heating air velocity distribution 4) Heating Temperature distribution...
11. Operation Range Mode OUTDOOR TEMPERATURE INDOOR TEMPERATURE INDOOR HUMIDITY COOLING 80% or less DRYING 80% or less NOTE • The assumed installation conditions are follows: - The pipe length(including elbow) is 24.6 ft. - The level difference is 0 ft. •...
13. Installation 13. Installation 13-1. Indoor unit 13-1. Indoor unit Choosing the installation location Checking and preparing accessories and tools Overview of installation location requirements Accessories Accessories in the indoor unit package 3.94 inch (100 mm) or more (recommended) 4.92 inch (125 mm) or MNADCH 4.92 inch (125 mm) or more (recommended)
13. Installation 13-1. Indoor unit Connecting the power and communication cables • When performing electrical and earthing works, be sure to comply with the 'technical standards of electrical installations' and the 'wiring regulations' (assembly cable) in the local regulations. • Tighten the terminal block screw to 0.89-1.33 lbf•ft [1.2-1.8 N•m (12-18 kgf•cm)].
13. Installation 13-1. Indoor unit Installing and connecting the drain hose Fixing the installation plate 1 Install the drain hose. You can install the indoor unit on a wall, window frame, or gypsum board. WARNING • Make sure that the wall, window frame, or gypsum board can withstand the weight of the indoor unit.
8 inch Samsung) • If the outdoor unit is installed at a height, ensure that its base is firmly fixed in position. • Make sure that the water dripping from the drain hose runs away correctly and safely.
13. Installation 13-2. Outdoor unit Outdoor unit installation The outdoor unit must be installed on a rigid and stable base to avoid any increase in the noise level and vibration, particularly if the outdoor unit is to be installed in a location exposed to strong winds or at a height, the unit must be fixed to an appropriate support(wall or ground). Fix the outdoor unit with anchor bolts.
13. Installation 13-2. Outdoor unit Outdoor Unit Support Outdoor Unit Outdoor Anchor bolt Unit Support Base Surface Designed to cut off residual vibration from • Ensure the wall will be able to support the weight of rack and outdoor unit. outdoor unit •...
Page 41
13. Installation 13-2. Outdoor unit Between Indoor unit and Outdoor unit Connection Cable Specifications(Common in use) ±10% • Power supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord. (Code designation IEC:60245 IEC 57 / CENELEC: H05RN-F or IEC:60245 IEC 66 / CENELEC: H07RN-F) When installing the indoor unit in a computer room or net work room, use the double shielded (Tape aluminum / polyester braid + copper ) cable of FROHH2R type.
Page 42
13. Installation 13-2. Outdoor unit CAUTION • You should connect the power cable into the power cable terminal and fasten it with a clamp. • The unbalanced power must be maintained within 2% of supply rating. – If the power is unbalanced greatly, it may shorten the life of the condenser. If the unbalanced power is exceeded over 4% of supply rating, the indoor unit is protected, stopped and the error mode indicates.
Page 43
13. Installation 13-2. Outdoor unit Connecting the Power Terminal • Connect the cables to the terminal board using the compressed ring terminal. Silver solder • Cover a solderless ring terminal and a connector part of the power cable and then connect it. +0.2 4(3/8) 9.5(3/8)
Page 44
13. Installation 13-2. Outdoor unit Refrigerant piping system Max. allowable length Actual pipe length L0 + H + L1 98.4 ft (30 m) or less 164.0 ft (50 m) or less Allowable height length Actual pipe length 65.6 ft (20 m) or less 98.4 ft (30 m) or less AC030/036MXSCCC 164.0 ft (50 m)
13. Installation 13-2. Outdoor unit Make at least one round: It will reduce noise and vibration The appearance of the unit may be different from the diagram depending on the model. CAUTION • After connecting pipes through the knock-out, cover the opening to prevent animals and debris from entering. Adding refrigerant (R-410A) The outdoor unit is loaded with sufficient refrigerant for standard piping.
Page 46
13. Installation 13-1. Indoor unit 13-2. Outdoor unit How to Calculate the Volume of Additional Refrigerant The volume of additional refrigerant is variable according to the length of the liquid pipe. Determine the liquid pipe length before adding refrigerant. This operation can only be performed by a qualified refrigeration specialist.
Page 48
14. Accessory Controller External room sensor MRW-TA Compatible interface module MIM-N01 External contact MIM-B14 interface module S-Converter MIM-C02N • In case you want more information about the accessories, please refer to the control and accessories TDB on pvi. samsung.com site.
Page 49
Samsung Electronics Co., LTD. / SE Head Office (Suwon Korea) 129, Samsung-Ro, Yeongtong-Gu, Suwon City, Gyeonggi-Do, Korea 16677 Website : www.samsung.com, http://btsp.samsunggsbn.com Email : airconditioner@samsung.com Images and data in this book may subject to change without prior notice.