3 . E X A M P L E A P P L I C A T I O N F O R I N P U T
OBJECTIVE: Configure any burglary condition on the GE Interlogix control panel to create a burglary condition on the
Videofied panel and to report an intrusion signal to the central station with a video from MotionViewer 1
Videofied Programmable Input Configuration -
TRANSMISSION: ENABLED
ALARM MODE: ALARM - Event only is transmitted
INPUT TYPE: OPEN
EVENT TYPE: INTRUSION
INPUT NAME: GE BURG
SIREN MODE: SIREN
MAPPING: MOTIONVIEWER 1
GE Interlogix Output Function Configuration -
Activated On: 0 - Zone Address
Zone Address: 49 -Output location (Output 3 = 49)
Segment 1: 24 - Not Ready
Segment 2: 2 - On if output should latch off if output should be timed