Download Print this page

DuraVent DVL Installation Instructions Manual page 4

Double-wall, close clearance connectors

Advertisement

LISTING:
UL and cUL listed by UL file # 14089
For installation in the United States and
Canada
PERMITS:
Contact local Building or Fire Officials about
permits, restrictions, and installation inspection
in your area.
CLEARANCE:
6" clearance to walls
8" clearance to ceiling
Clearances are measured at a 90 degree
angle to the pipe.
APPLICATION:
Used to connect an appliance that burns wood,
coal, oil, or gas to a DuraVent Factory Built
chimney system tested and listed to UL103HT.
Can be used anywhere single wall stove pipe
is allowed.
Stove pipe installation should be as short and
straight as reasonably possible.
DVL stove pipe is required for use with a solid
fuel burning appliances installed in a mobile
home.
NOTES:
Use only authorized DuraVent DVL parts.
Do not mix with single wall stove pipe.
Do not mix with other products or improvise
solutions. Do not install damaged parts.
All wood burning appliances require their own
separate connector pipe and chimney system.
DO NOT ENCLOSE DOUBLE-WALL
CONNECTOR PIPE or fittings and/or pass
through walls, ceilings, attics or closets.
DVL Pipe cannot be cut.
DVL (Close Clearance Connector) pipe will
exhibit a moderate paint-like odor and smoke
during the first few uses. This is the normal
4
curing of the finish and will disappear after a
few uses of the appliance.
Pipe
Tee
Rear exiting stove
to a through the
wall Chimney
MOBILE HOMES: Solid fuel appliances
installed in mobile homes must be listed and
bear the label of a testing agency approved
by the Department of Housing and Urban
Development (HUD), and must be installed
exactly in accordance with the manufacturer's
installation instructions. DuraVent's DVL
stovepipe complies with the requirements
for "mobile home" use on HUD approved
appliances- Refer to stove manufacturer's
installation instructions. Those instructions will
also clearly state all clearance requirements
and approved installation configurations. DO
NOT USE THIS PRODUCT IN A MOBILE
HOME IF the stove to be installed is not listed
for use in a mobile home.
Chimney
Adapter
Elbow
Telescop-
ing pipe or
Adjustable
pipe
Pipe
Stove
Adapter
Top exiting stove
to a through the
ceiling Chimney
Figure 1

Advertisement

loading