2.2
Connecting the converter
You can connect a SINAMICS CONNECT device to one of the
following converters via the RS232 interface on the converter
specific optional module or Control Unit:
• SINAMICS V20
• SINAMICS G120 series (G120D excluded)
• MICROMASTER 440
Interface assignment (converter side)
RS232 interface on
Module
the module
BOP Interface Module
for SINAMICS V20
Control Unit for
SINAMICS G120 series
(G120D excluded)
PC converter connector
module for
MICROMASTER 440
Interface assignment (device side)
X121
RS232 interface
on the device
Pin No. Pin name Pin No. Pin name
1
PE
2
PE4
3
M
4
RX4
5
TX4
6
PE3
7
M
8
RX3
9
TX3
10
PE2
11
M
12
RX2
13
TX2
14
PE1
15
M
16
RX1
17
TX1
Wiring example
RXD
1
TXD
2
GND
3
...
RJ45 connector
socket
SINAMICS V20
BOP Interface Module
Note
To achieve better EMC performance, Siemens recommends that you
observe the following when connecting the device:
• Use the shielded cable for RS232 communication between the
converter and the device.
• Do not connect the device to the ground via the PE terminal (pin 1 at
X121, pin 17 at X122).
• Route the signal cables and the power cables separately in different
cable conduits.
Connecting example
2
1
3
Note
Siemens recommends that you use the signal cable with a length less
than 3 m.
Pin
Signal
Description
No.
name
1
RXD
Receive data
2
TXD
Transmit data
3
GND
Signal ground
8
1
2
RXD
Receive data
1
5
3
TXD
Transmit data
6
9
5
GND
Signal ground
2
RXD
Receive data
1
5
3
TXD
Transmit data
6
9
5
GND
Signal ground
X122
Description
17
PE
Protective earth
16
PE8
Protective earth
15
M
Signal ground
14
RX8
Receive data
13
TX8
Transmit data
12
PE7
Protective earth
11
M
Signal ground
10
RX7
Receive data
9
TX7
Transmit data
8
PE6
Protective earth
7
M
Signal ground
6
RX6
Receive data
5
TX6
Transmit data
4
PE5
Protective earth
3
M
Signal ground
2
RX5
Receive data
1
TX5
Transmit data
Cable shield
17
TX1
16
RX1
15
M
14
PE1
...
1
PE
X121
SINAMICS CONNECT
2.3
Switching on the device
1
Power
9 V D
On
C
t o 3 6
V D C
P o w e
r
S u p p
l y
Identifying the converter (optional)
2.4
The SINAMICS CONNECT supports port modes of "Auto" and
"Manual" which you can set via the SINAMICS CONNECT Web
server. For more information, see Section "Configuring ports" in the
SINAMICS CONNECT Operating Instructions.
• Auto (default): Keep pressing the USER button for at least 1
second to identify the converter at the port, or wait (up to 5
minutes) for the device to identify the converter.
• Manual: You must set the basic parameters of the converter
manually via the Web server.
WARNING
Safety notice for connections with LAN X2 connector
Improper connection might cause high voltages. The LAN X2 connector
is designed for connection to a Local Area Network "Environment A"
according to IEEE802.3 or "Environment 0" according to IEC TR 62102
only.
• Do not connect the LAN X2 connector directly to the telephone
network or a WAN (Wide Area Network).
User documentation online
https://support.industry.siemens.com/cs/ww/en/ps/25436/man
Central Technical Support
https://support.industry.siemens.com
Service and spare parts
https://support.industry.siemens.com/sc/ww/en/sc
Illustrations
This document contains illustrations of the described devices and
accessories. The illustrations may deviate from the particularities of the
delivered device and accessories.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency
with the hardware and software described. Since variance cannot be
precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary
corrections are included in subsequent editions.
Siemens AG
Digital Factory
Motion Control
Postfach 31 80
91050 ERLANGEN
Germany
© Siemens AG 2018. All rights reserved
A5E45421417-002
10/2018
2
+

Advertisement

loading

This manual is also suitable for:

Sinamics connectSinamics g120 seriesSinamics v20