Rigol RP7000S Series User Manual
Rigol RP7000S Series User Manual

Rigol RP7000S Series User Manual

Single-ended active probe
Table of Contents

Advertisement

Quick Links

R
I
G
O
L
R
I
G
O
L
用户手册
RP7000S 系列单端有源探头
2013 年 11 月
RIGOL Technologies, Inc.

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RP7000S Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Rigol RP7000S Series

  • Page 1 用户手册 RP7000S 系列单端有源探头 2013 年 11 月 RIGOL Technologies, Inc.
  • Page 3: 保证和声明

    © 2013 北京普源精电科技有限公司版权所有。 商标信息 RIGOL 是北京普源精电科技有限公司的注册商标。 文档编号 UGE21001-1110 声明  本公司产品受已获准及尚在审批的中华人民共和国专利的保护。  本公司保留改变规格及价格的权利。  本手册提供的信息取代以往出版的所有资料。  对于本手册可能包含的错误,或因手册所提供的信息及演绎的功能,以及 因使用本手册而导致的任何偶然或继发的损失,RIGOL 概不负责。 未经 RIGOL 事先书面许可不得影印复制或改编本手册的任何部分。  产品认证 RIGOL 认证本产品符合中国国家产品标准和行业产品标准及 ISO9001:2008 标 准和 ISO14001:2004 标准,并进一步认证本产品符合其它国际标准组织成员的 相关标准。 联系我们 如您在使用此产品或本手册的过程中有任何问题或需求,可与 RIGOL 联系: 电子邮箱:service@rigol.com 网址:www.rigol.com RP7000S 用户手册...
  • Page 4: 安全术语和符号

    RIGOL 安全术语和符号 本手册中的术语。以下术语可能出现在本手册中: 警告 警告性声明指出可能会危害操作人员生命安全的条件和行为。 注意 注意性声明指出可能导致本产品损坏或数据丢失的条件和行为。 产品上的术语。以下术语可能出现在产品上: 危险 表示您如果进行此操作可能会立即对您造成危害。 警告 表示您如果进行此操作可能会对您造成潜在的危害。 注意 表示您如果进行此操作可能会对本产品或连接到本产品的其他设备造 成损坏。 产品上的符号。以下符号可能出现在产品上: 高电压 安全警告 保护性 壳体接地端 测量接地端 接地端 RP7000S 用户手册...
  • Page 5: 文档概述

    RIGOL 文档概述 本手册用于指导用户快速了解 RP7000S 系列单端有源探头及其使用方法,并提 供保养与清洁等服务信息。 RP7000S 系列单端有源探头包含如下型号。 型号 带宽 PR7150S >1.5GHz RP7080S >800MHz 本手册主要内容包括: RP7000S 系列单端有源探头概述  简介探头,包括:一般性检查、探头尺寸、标准附件等。 使用 RP7000S 系列单端有源探头  介绍如何使用探头,包括:连接示波器、探头前端的使用、更换探头配件、 调节偏移电压、校准探头等。  保养与清洁  保修概要  性能指标 RP7000S 用户手册...
  • Page 6: Table Of Contents

    RIGOL 目录 保证和声明 ....................I 安全术语和符号 ..................II 文档概述 ....................III RP7000S 系列单端有源探头概述 ..............1 探头简介 ..................2 一般性检查 ..................2 探头尺寸 ..................3 附件和选件 ..................4 有源探头放大器 ................6 探头前端 ..................7 使用 RP7000S 系列单端有源探头 .............9 连接示波器 ..................10 手持式单端探头前端的使用.............. 12 更换探头配件...
  • Page 7: Rp7000S 系列单端有源探头概述

    RIGOL RP7000S 系列单端有源探头概述 本部分指导用户快速了解 RP7000S 系列单端有源探头。 主要内容包括:  探头简介  一般性检查  探头尺寸  附件  有源探头放大器  探头前端 RP7000S 用户手册...
  • Page 8: 探头简介

    RIGOL 探头简介 RP7000S是针对于高频解决方案的单端有源探头。RP7000S使用快插式探头前 端,支持探头前端更换,提高了探头可用性。允许用户更换探头尖,延长探头的 使用寿命。更换不同的接地片可以适应不同的待测点间距。RP7000S与RIGOL DS6000/DS4000系列示波器的自动识别接口兼容,可由该接口自动识别和配置。 其卡入式BNC连接器使得与示波器的连接更加方便。RP7000S提供丰富的附件和 选件,并且诸多部件采用可替换的设计原则,可方便的应用于不同的测试测量解 决方案。 一般性检查 1. 检查运输包装 如运输包装已损坏,请保留被损坏的包装或防震材料,直到货物经过完全 检查且探头通过电性和机械测试。 因运输造成探头损坏,由发货方和承运方联系赔偿事宜。RIGOL公司恕不 进行免费维修或更换。 2. 检查探头 若存在机械损坏或缺失,或者探头未通过电性和机械测试,请联系您的 RIGOL 经销商。 3. 检查附件 请根据本手册附件和选件一节检查随机附件,如有损坏或缺失,请联系您 的RIGOL经销商。 RP7000S 用户手册...
  • Page 9: 探头尺寸

    RIGOL 探头尺寸 图 1 给出了 RP7000S 系列单端有源探头主体部分的尺寸示意图。 图 1 探头尺寸 RP7000S 用户手册...
  • Page 10: 附件和选件

    RIGOL 附件和选件 本节列出了 RP7000S 系列单端有源探头套件及其标准附件。所列部件均可通过 RIGOL 订购。RP7150S 单端有源探头套件(订货号为 RP7150S)包含表 1 所 列全部标准附件。如需单独订购附件,请参考表 1。RP7080S 单端有源探头套 件(订货号为 RP7080S)包含表 2 所列全部标准附件。如需单独订购附件,请 参考表 2。 表 1 RP7150S 单端有源探头套件(订货号为 RP7150S)标准附件 名称 订货号 数量 PCK100 有源差分探头校准套件 PCK100 RP7150S 有源探头放大器 RP7S-0150 RP7S-0205 手持式单端探头前端 91Ω 探头尖 RP7-0405 RP7-0501 尖形直接地片...
  • Page 11 RIGOL 表 2 RP7080S 单端有源探头套件(订货号为 RP7080S)标准附件 名称 订货号 数量 PCK100 有源差分探头校准套件 PCK100 RP7080S 有源探头放大器 RP7S-0080 RP7S-0205 手持式单端探头前端 91Ω 探头尖 RP7-0405 RP7-0501 尖形直接地片 RP7-0502 尖形弯接地片 RP7-0503 齿形直接地片 RP7-0504 齿形弯接地片 RP-0203 标识环(黄、粉、浅蓝、深蓝) RP7S-0601 用户手册 RP7-0602 探头包 RP7-0603 储物盒 注意:本部分所列附件仅供参考,请以产品实物为准。 RP7000S 用户手册...
  • Page 12: 有源探头放大器

    RIGOL 有源探头放大器 有源探头放大器(图 2)作为有源探头的主体部件,具有大于 1.5GHz 的带宽, 它一端可与 DS6000/DS4000 系列示波器连接,另一端可灵活插入用户所需的探 头前端。 正负标识 图 2 有源探头放大器 有源探头放大器与探头前端通过插拔方式进行连接。 使用单端探头时, 在插拔的 过程中,请注意二者的正负极性。极性接反可能造成有源探头性能下降甚至损坏 探头。 注意 手持式单端探头前端在连接处有正负标识。 RP7000S 用户手册...
  • Page 13: 探头前端

    RIGOL 探头前端 RP7000S 支持手持式单端探头前端。使用手持式单端探头前端,旋转单端接地 片以改变接地片与探头尖的间距,如图 3 所示。 图 3 手持式单端探头前端 其中,探头尖与单端接地片是标准附件,如图 4 和图 5 所示。这两种部件均为 可替换部件,如果在使用过程中被损坏,您可以方便地更换新的探头尖或单端接 地片,更换方法请参考更换探头配件。 RP7000S 提供四种单端接地片以适应不同的测量要求,各接地片的结构如图 5 所示。 尖形直接地片:适用于近距离测试点的测量。 尖形弯接地片:适用于较远距离测试点的测量。 齿形直接地片:适用于近距离芯片管脚测试点的测量。 齿形弯接地片:适用于较远距离芯片管脚测试点的测量。 图 4 探头尖 RP7000S 用户手册...
  • Page 14 RIGOL (a) 尖形直接地片 尖形弯接地片 齿形直接地片 齿形弯接地片 图 5 接地片 RP7000S 用户手册...
  • Page 15: 使用 Rp7000S 系列单端有源探头

    RIGOL 使用 RP7000S 系列单端有源探头 在使用 RP7000S 系列单端有源探头的过程中,正确的使用方法可以保证探头性 能,延长探头的使用寿命并保证信号测量结果的有效性。本部分将详细介绍 RP7000S 系列单端有源探头的使用方法。 主要内容包括:  连接示波器  手持式单端探头前端的使用  更换探头配件  调节偏移电压  校准探头 RP7000S 用户手册...
  • Page 16: 连接示波器

    RIGOL 连接示波器 RP7000S 系列单端有源探头与 RIGOL DS6000/DS4000 系列示波器正确连接 后,示波器自动识别探头并通过前面板为探头提供电源和偏移电压。此时,您可 以通过示波器前面板菜单调节偏移电压 (参考调节偏移电压一节) 和校准探头 (参 考校准探头一节)等操作。 请按照如下步骤连接探头与示波器: 将探头前端与有源探头放大器连接。连接时请注意正负极性。 将有源探头放大器的另一端连接到示波器通道输入或外部触发输入连接器, 并推到紧闭的位置。 RP7000S 用户手册...
  • Page 17 RIGOL 使用任意探头辅助装置将其连接到待测电路中。 需断开探头和示波器的连接时,首先按住探头上的按钮(见左下图) ,将连 接器从示波器拔出后(见右下图) ,松开按钮即可。 注意 不要试图从示波器 BNC 连接器上扭动探头,否则,可能导致探头 损坏。 RP7000S 用户手册...
  • Page 18: 手持式单端探头前端的使用

    RIGOL 手持式单端探头前端的使用 手持式单端探头前端的有效带宽大于 1.5GHz,探头尖与单端接地片的间距可以 通过拨动单端接地片进行调节,探头尖和单端接地片允许更换,从而延长探头的 使用寿命。 使用手持式单端探头前端,您可以方便的测量单端信号。在进行信号测量时,单 端接地片需要接地。探头前端与有源探头放大器连接时,注意二者连接处的正负 标识。 手持式单端探头前端结构如图 6 所示。 ① ③ ② 图 6 手持式单端探头前端 ① 手持式单端探头前端(RP7S-0205) 。 91Ω 探头尖(RP7-0405) 。 ② 尖形直接地片:转动接地片调节接地片与探头尖的间距(0mm 至 5mm) ③ (RP7-0501) 。 注意 请将接地片就近接地。 RP7000S 用户手册...
  • Page 19: 更换探头配件

    更换过程中请小心操作,以免破坏连接部分而影响探头的性能。 更换方法: ① 断开探头前端与有源探头放大器的连接。 ② 将新的探头前端垂直插入有源探头放大器。连接单端探头前端时,请 注意正负极性。 更换探头尖 探头尖与探头前端以螺纹的方式进行连接,拆卸和安装探头尖时请注意旋 转的方向和力度。 更换单端接地片 更换单端接地片时,请确保接地片与铜管紧密连接,以保证探头的性能。 调节偏移电压 RIGOL DS6000/DS4000 系列示波器系统为 RP7000S 系列单端有源探头提供偏 移电压。 此偏移电压用于将超出有源探头放大器输入动态范围的被测信号调整至 适当的范围,以保证被测信号的完整性。 此偏移电压可通过示波器前面板菜单进行调节。调整方法如下: 按照连接示波器一节所述方法,将 RP7000S 系列单端有源探头连接至 DS6000/DS4000 系列示波器的通道输入端(比如:CH1) 。 打开 DS6000/DS4000 示波器的探头偏移电压控制菜单 (前面板操作: CH1  探头  偏置电压) ,使用旋钮调节偏移电压值。 RP7000S 用户手册...
  • Page 20: 校准探头

    RIGOL 校准探头 在使用 RP7000S 系列单端有源探头前,您可以使用 PCK100 有源探头校准套件 对探头进行校准。使用该套件校准 RP7000S 有源探头的步骤如下: 使用 1 个 BNC-SMA 连接器分别连接校准板和连接线的 BNC(母头), 然后将 另一个 BNC-SMA 连接器连接至校准板的另一端(称作部件 1)。 连接 RP7000S 有源探头至示波器的模拟通道(CH1-CH4,本文以 CH1 为例 进行说明)。 打开示波器的探头校准控制菜单(前面板操作:CH1  探头  探头校 准) ,此时示波器的用户界面会弹出校准提示信息,请按照提示信息将部件 1 连接至示波器,通常情况下,将连接器的 BNC(公头)连接至相应的模拟通 道,将连接线的 BNC(公头)连接至后面板 [Trig Out/Calibration] 端口。...
  • Page 21: 保养与清洁

    RIGOL 保养与清洁 保养: 请勿将探头及其附件放置在长时间受到日照的地方。 注意 请勿使任何腐蚀性的液体沾到探头及其附件上。 清洁: 请根据使用情况经常对探头及其附件进行清洁。方法如下: 断开探头与示波器或电压源的连接。 用潮湿但不滴水的软布(可使用柔和的清洁剂或清水)擦试探头及其附件 外部的浮尘。 警告 在重新使用前,请确认探头已经干透,避免因水分造成电气短路甚 至人身伤害。 RP7000S 用户手册...
  • Page 22: 保修概要

    RIGOL 保修概要 RIGOL 承诺其生产仪器的主机和附件, 在产品保修期内无任何材料和工艺缺陷。 在保修期内,若产品被证明有缺陷,RIGOL 将为用户免费维修或更换。详细保 修条例请参见 RIGOL 官方网站或产品保修卡的说明。 欲获得维修服务或保修说 明全文,请与 RIGOL 维修中心或各地办事处联系。 除本概要或其他适用的保修卡所提供的保证以外,RIGOL 公司不提供其他任何 明示或暗示的保证, 包括但不局限于对产品可交易性和特殊用途适用性之任何暗 示保证。在任何情况下,RIGOL 公司对间接的,特殊的或继起的损失不承担任 何责任。 RP7000S 用户手册...
  • Page 23: 性能指标

    RIGOL 性能指标 技术指标 RP7150S RP7080S 指标名称 >1.5GHz >800MHz 带宽 <265ps <465ps 上升时间(计算值) 1GHz (DS6104 或 800MHz (DS6104 或 系统带宽 DS6102) DS6102) <1pF 输入电容 100kΩ±2% 输入电阻 ±6.25V 输入动态范围 10:1 ±2% 直流衰减精度 <30mV 零点偏移误差 校准前 <5mV 校准后 ±12V 偏移电压范围 <3%当前量程 偏移精度 校准前...
  • Page 24 RIGOL 一般规格 环境条件 操作环境 存放环境 +5°C ~+40°C -40°C ~+70°C 温度 0 RH~80% RH 0 RH~90% RH 湿度 4600m 15300m 海拔 1.2W 功耗 132±10g 1305±50g 重量 1.4m 线长 [1] 典型值,其技术指标会随着示波器的档位不同而改变。 [2] CAT I 和 CAT II 的定义 装置种类(超压种类)I:信号电平,特殊设备或部分设备,无线电通讯和 电子等,相对装置种类(超压种类)II 有更小的瞬态电压。 装置种类(超压种类)II:局部电平,器具,可携带设备等,相对装置种类...
  • Page 25 User’s Guide RP7000S Series Single-Ended Active Probe Nov. 2013 RIGOL Technologies, Inc.
  • Page 27: Guaranty And Declaration

    Notices RIGOL products are protected by patent law in and outside of P.R.C.  RIGOL reserves the right to modify or change parts of or all the  specifications and pricing policies at company’s sole decision. Information in this publication replaces all previously corresponding ...
  • Page 28: Safety Terms And Symbols

    RIGOL Safety Terms and Symbols Terms in this Manual. The following terms may appear in this manual: WARNING Warning statements indicate the conditions or practices that could result in injuries or loss of life. CAUTION Caution statements indicate the conditions or practices that could result in damage to this product or loss of data.
  • Page 29: Document Overview

    Document Overview This document is used to guide users to get a quick understanding of the RP7000S series single-ended active probe as well as its using method. Besides, this document gives service information relating to general care and cleaning. RP7000S series single-ended active probe includes the following model.
  • Page 30 Probe Dimensions ................3 Accessories and Options ..............4 Active Probe Amplifier ............... 6 Probe Head ..................7 To Use RP7000S Series ................9 To Connect to the Oscilloscope............10 To Use Hand-held Single-ended Probe Head ........12 To Replace Probe Accessories ............13 To Adjust Offset Voltage ..............
  • Page 31: Rp7000S Series Overview

    RIGOL RP7000S Series Overview This chapter guides users to quickly get familiar with the RP7000S series single-ended active probe. Main topics: Probe Introduction  General Inspection  Probe Dimensions  Accessories and Options  Active Probe Amplifier  Probe Head ...
  • Page 32: Probe Introduction

    RP7000S is compatible with the auto-identification port of RIGOL DS6000/DS4000 series oscilloscope and can be recognized and configured automatically by this port. Its snap-in BNC connector enables easier connection with the oscilloscope.
  • Page 33: Probe Dimensions

    Please check the accessories according to Accessories and Options in this guide. If the accessories are incomplete or damaged, please contact your RIGOL sales representative. Probe Dimensions Figure 1 shows the dimensions of the main parts of RP7000S series single-ended active probe. Figure 1 Probe Dimensions RP7000S User’s Guide...
  • Page 34: Accessories And Options

    RIGOL Accessories and Options This section lists the probe kits, standard accessories of the RP7000S series single-ended active probe respectively. All the components listed below can be ordered from RIGOL. RP7150S Single-ended Active Probe Kit (the ordering number is RP7150S) contains all the accessories listed in Table 1. If any accessory or option needs to be ordered separately, please refer to Table 1.
  • Page 35 RIGOL Table 2 Standard Accessories of RP7080S Single-Ended Active Probe Kit (Ordering No. is RP7080S) Name Ordering NO. PCK100 Active Differential Probe PCK100 Calibration Kit RP7080S Single-ended Active Probe RP7S-0080 Amplifier Hand-held Single-ended Probe Head RP7S-0205 91Ω Probe Tip RP7-0405...
  • Page 36: Active Probe Amplifier

    RIGOL Active Probe Amplifier The active probe amplifier (Figure 2), with more than 1.5GHz bandwidth, is a main component of the active probe. One end of the active probe amplifier can be connected to the DS6000 and DS4000 series oscilloscope and the other end can be connected to the desired probe head.
  • Page 37: Probe Head

    RIGOL Probe Head RP7000S supports hand-held single-ended probe head. Before using it, rotating the single-ended ground collar adjusts the spacing between the single-ended ground collar and probe tip, as shown in Figure 3. Figure 3 Hand-held Single-ended Probe Head Wherein, as shown in Figure 4 and Figure 5, probe tip and single-ended ground collar are standard accessories and are both replaceable.
  • Page 38 RIGOL Figure 4 Probe Tip Straight Acuminate Ground Collar Curved Acuminate Ground Collar Straight Dentiform Ground Collar Curved Dentiform Ground Collar Figure 5 Ground Collar RP7000S User’s Guide...
  • Page 39: To Use Rp7000S Series

    During the use of RP7000S series single-ended active probe, correct operations can ensure the probe performance, prolong the service life of the probe and ensure the effectiveness of the signal measurement result. This chapter introduces in detail the using method of the RP7000S series single-ended active probe. Main Topics: To Connect to the Oscilloscope ...
  • Page 40: To Connect To The Oscilloscope

    RIGOL To Connect to the Oscilloscope After RP7000S is connected correctly to a RIGOL DS6000 or DS4000 series oscilloscope, the oscilloscope recognizes the probe automatically and provides both power and offset voltage to the probe. You can adjust the offset voltage (refer to To Adjust Offset Voltage) and calibrate the probe (refer to To Calibrate the Probe) by the front panel menu of the oscilloscope.
  • Page 41 RIGOL Use any probe auxiliary device to connect the probe to the circuit to be tested. To disconnect the probe from the oscilloscope, press the button on the probe (as shown in the left figure below), pull the connector straight out of the oscilloscope (as shown in the right figure below) and then release the button.
  • Page 42: To Use Hand-Held Single-Ended Probe Head

    RIGOL To Use Hand-held Single-ended Probe Head Known from Probe Head, RP7000S can easily change the probe head by using the method introduced in To Replace Probe Accessories. This chapter introduces how to use the probe heads respectively. The hand-held single-ended probe head provides an effective bandwidth of more than 1.5GHz.
  • Page 43: To Replace Probe Accessories

    RIGOL Hand-held single-ended probe head (RP7S-0205). ① 91Ω probe tip (RP7-0405). ② Straight acuminate ground collar: rotating the ground collar adjusts the ③ spacing (0mm to 5mm) between the ground collar and probe tip (RP7-0501). CAUTION Ground the ground collar when using the hand-held single-ended probe.
  • Page 44: To Adjust Offset Voltage

    (front panel operation: CH1  Probe  Bias Voltage) and rotate the knob to adjust the value. To Calibrate the Probe Before using RP7000S series single-ended active probe, you can calibrate it using the PCK100 active probe calibration kit. The calibration procedures are shown as below:...
  • Page 45 Note: Relative specifications of the RP7000S series single-ended active probe depend on the calibration operation. After the calibration is finished, the DC gain, offset voltage zero and offset gain will be calibrated. User can query the information about the manufacturer, model, serial number and the last calibration time of the probe through CH1 ...
  • Page 46: General Care And Cleaning

    RIGOL General Care and Cleaning General Care: Do not place the probe and its accessories in places where they will be exposed to sun light for long periods of time. CAUTION Keep the probe and its accessories away from any corrosive liquid.
  • Page 47: Warranty

    RIGOL warrants that its products mainframe and accessories will be free from defects in materials and workmanship within the warranty period. If a product is proven to be defective within the respective period, RIGOL guarantees the free replacement or repair of products which are approved defective.
  • Page 48: Specifications

    RIGOL Specifications Technical Specifications Item RP7150S RP7080S Bandwidth >1.5GHz >800MHz Rise Time <265ps <465ps System 1GHz (DS6104 or DS6102) 800MHz (DS6104 or DS6102) Bandwidth Input Capacitance <1pF Input Resistance 100kΩ±2% Input Dynamic ±6.25V Range DC Attenuation 10:1 ±2% Zero Offset Error <30mV before calibration...