Procedure 4-5: Wall Mount The 9764 Cmco - Alcatel-Lucent 9764 Series Manual

Cmco lte 2x2w v1.1 / 2x5w v1.2
Hide thumbs Also See for 9764 Series:
Table of Contents

Advertisement

Installation
Installation
....................................................................................................................................................................................................................................
Procedure 4-4: Wall mount the 9764 CMCO
Purpose
This topic describes the procedures to be followed when installing the Alcatel-Lucent
9764 Compact Metro Cell Outdoor onto a wall or solid flat surface
Prerequisites
A site survey has been conducted and a location for the device has been selected that is
both central to the public space and elevated in order to maximize coverage. Before
installation begins you should ensure the following are in place:
 Ensure adequate clearance is provided for service access.
 Ground cable has been routed and the site grounding system is in place.
 Backhaul cable has been routed and is in place.
 Any site specific fixing materials are available (for example, bolts, washers and wall
plug materials).
Attention: The 9764 CMCO must be mounted with the appropriate mounting
hardware suitable for the various supporting structures, building materials and
construction methods. Following a site survey, it is the responsibility of the customer
to ensure that:
 The installation support structure is adequate and compliant with ICC IBC (2012):
 The appropriate mounting hardware and any necessary recommended supporting
Mounting requirements and materials
The 9764 CMCO can be easily mounted onto solid concrete or wooden flat surface. Refer
to the following for the installation kits, anchor materials and tools for the installation
type:
 For wall mount, refer to
 For a list of standard tools that may be required to support the installation, see
required for installation" (p.
Before you begin
Record the 9764 CMCO 18 digit serial number before mounting onto a wall or flat
surface.
....................................................................................................................................................................................................................................
International Building Code, and all other national and local codes.
anchor fixings are used.
"Wall mount installation requirements" (p.
Use pursuant to applicable agreements
3-3).
Alcatel-Lucent – Proprietary
3-7).
"Tools
4-28

Hide quick links:

Advertisement

Table of Contents
loading