Hot Water Tank Module - Keurig B3000 Service Manual

Hide thumbs Also See for B3000:
Table of Contents

Advertisement

E. HOT WATER TANK MODULE (Located in the back right side of brewer)
See REMOVAL of OUTER PANELS (page 36). After completion of panel removal, the technician
must attach an ESD wrist strap to themselves and the metal base plate of the brewer.
NOTE: Before disconnecting the two hoses on top of the module, make a note of where they are
attached. The LEFT hose comes from the Cold Water Tank. The RIGHT hose goes to the Puncture
Mechanism Module. These hoses MUST be reinstalled correctly. If they are not, then there will be no
water dispensed during the brew cycle. Needle nose pliers can be used to release the two hose clamps
that secure these hoses. Care must be taken when removing these clamps so that damage to these hoses
does not occur.
TO COLD WATER TANK
1. Disconnect the two hoses on the top Hot Water Tank.
2. Disconnect the two wire harness connections on the right side of the Hot Water Tank module.
TO PUNCTURE MECHANISM
B3000 SERVICE MANUAL
60-200807-000, REV C
46

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents