LEAK CHECKING YOUR SIDE BURNER

Le a k Testin g
1.
Turn the side burner control knob to
2.
Turn ON the home gas source.
3.
Use a clean paint brush and a 50/50 mild soap and water solution. Brush soapy solution onto areas indicated. (see Figure C).
4.
If "growing" bubbles appear, there is a leak. Close main gas supply and re-tighten all connections. If leaks cannot be stopped do not try to repair. Contact licensed
plumber for correction.
5.
The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing on that system at test pressures in
excess of ½ psig (3.5kPa).
6.
The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than ½ psig (3.5kPa).
7.
IMPORTANT: You should leak check each piping connection.
Gas Supply piping
Gas Shut off Valve
Enclosure
Side
burner
FIGURE C
IMPORTANT: You should leak
check each piping connection.
Examples of possible locations
are shown here with a
OFF.
Check for
leaks here
Check for
leaks here
Check for
leaks here
Check for
leaks here
Regulator
R
Check for
leaks here
P a ge 7
IMPORTANT: You should leak
check each piping connection.
Examples of possible locations
are shown here with a
Side burner Connection
Example of "Growing" Bubbles
indicating a gas leak.