Char-Broil 463670619 Product Manual page 6

Medallion built-in side burner
Table of Contents

Advertisement

Available languages

Available languages

PLANNING FOR INSTALLATION
supply pipe be installed outside the side burner enclosure. This valve will allow
safe access to shut off the natural gas supply to the built in side burner in the
event of an emergency. A convenient location for the safety valve is at the rear of
the side burner enclosure. This allows for easy access to connect the gas piping
in the enclosure to the shut-off valve. If a gas supply stub-up is used inside the
side burner enclosure,
an external shut-off valve close to the side burner is still recommended.
NOTE: A licensed plumber should be used to install the gas
supply line to the side burner.
The gas supply line from your home should be routed to the left rear corner of the
side burner inside the side burner enclosure. It is recommended that hard piping
be used to connect to the inlet of the natural gas appliance regulator. Constant
movement of flexible gas lines could cause fatiguing of the flexible line and result
in gas leakage. If hard piping is not used for the home supply line, any flexible gas
lines must be supported within the enclosure to prevent constant movement and
fatiguing.
PRIOR TO INSTALLING THE SIDE BURNER IN THE ENCLO-
SURE:
1. Turn the home gas source to the OFF position.
2. Install the supplied 4 inch water column regulator to your hard piped, na-
trual gas supply line. It is recommended that the regulator be located inside
the side burner enclosure. The inlet and outlet sides fo the the regulator are
noted by markings on the regulator body. SEE FIGURE A.
3. The side burner is now ready to be installed in the enclosure. Take care not
to damage the regulator during installation. Two persons are required to lift
the side burner and place in the enclosure.
Hard Pipe
Regulator
Enclosure
FIGURE A
Gas In
Gas Shut off Valve
Side
burner
P a ge 6
AFTER INSTALLING THE Side burner IN THE ENCLOSURE:
1. Use hard pipe with adapters or flexible tubing with adapters to connect the
outlet of the regulator to the side burner's 5/8" gas flare fitting. Adapters,
fittings or tubing are not supplied. See FIGURE B for piping suggestions.
2. Confirm the side burner control knob is turned to
3. Turn ON the home gas source.
4. Proceed to Leak Testing.
MIP to
Male flare
R
adapter
FIP to
Male flare
adapter
FIGURE B
Male flare fitting at side burner
OFF.
FIP to
Male flare
adapter
R
R
Hose with
female flare
fittings
C HA RB ROIL . CO M

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents