MONOGRAM REFRIGERATORS
~RIGERATION
SYSTEM
The refrigeration system, not removable as
a separate unit, consists of:
+
a reciprocating type compressor,
a fin-and-tube type condenser,
+
a condenser loop,
+
a dryer,
~
a fin-and-tube type evaporator and
~
a heat exchanger
Refrigerant Flow
tl
~~e
compressor discharges hot high pressure
rigerant gas into the condenser.
The
denser is cooled by a fan and the cooled gas
is converted to a high pressure liquid. The high
pressure liquid enters the condenser loop,
passing first down the mullion side of the
freezer compartment, across the bottom, then up
the left side and back to the unit compartment,
flowing through the dryer where any moisture is
removed.
The warm dry liquid then enters the
capillary that meters the flow of liquid
refrigerant entering the evaporator.
The liquid
refrigerant boils and vaporizes inside the
evaporator, picking up heat from inside the
cabinet.
Refrigerant vapor is then returned to
the compressor through the suction tube.
The
heat exchanger provides for warming of the
suction tube by the capillary and cooling of the
c~pillary
by the suction tube.
- 5 -
ZIS MODELS
SUCTION
LINE
~
...
EVAP.
r;======:dJ/
CAPilLARY'"",
t
DRYER/
DISCHARGE
TUBE
/ '
CONDENSER
Y
~CONDENSER
./'
lOOP