DIAGNOSIS
Electrical System
Wiring harness connectors, located in the
unit compartment, provide a means for
testing electrical components of the
refrigerator.
An ohmmeter can be used to
test between the terminals in each
connector, after removing the top panel,
disconnecting the power cord, and
separating the harness connectors.
Resistance readings of individual
components should be performed with the
component isolated to avoid parallel
circuits.
Refer to the wiring diagram for
circuitry.
To perform a direct start test of the
compressor, follow the standard Direct
Start Test procedure using the terminal
adapter and test harness.
Refrigeration System
To access the refrigeration system, a
service valve must be attached to the low
pressure process tube extending from the
compressor case. For diagnosis of the
refrigeration system, use the Standard
Compressor Capacity Test or the
Leak-Restriction test, as required .
- 27 -