Metrologic MS2122 StratosE Installation And User Manual page 36

Hide thumbs Also See for MS2122 StratosE:
Table of Contents

Advertisement

T
ROUBLESHOOTING
Symptom
All Interfaces
The unit beeps at some
bar codes but NOT for
others of the same bar
code symbology.
RS232 Only
The unit powers up OK
and scans OK but does
not communicate
properly to the host.
The host is receiving
data but the data does
not look correct.
Characters are being
dropped.
Aux Port Operation With Any Interface
The secondary scanner
is not functioning.
The secondary scanner
powers up but data is
not relayed to the host.
* Refer to the MS2xxx Stratos Series Configuration Addendum (
Auxiliary Port, Quick Start for a Secondary Metrologic Scanner.
32
Possible Cause(s)
The bar code may have been
printed incorrectly.
The scanner is not configured
correctly for this type of bar
code.
The minimum symbol length
setting does not work with the
bar code.
The com port at the host is
not working or is not
configured properly.
The cable is not connected to
the proper com port.
The com port is not operating
properly.
The scanner and host may
not be configured for the
same interface.
The intercharacter delay
needs to be added to the
transmitted output.
The secondary scanner cable
may not be connected to the
proper port on the StratosH.
The auxiliary com port may
not be operating properly.
Check if it is a check digit, character or border problem.
Check if check digits are set properly.
Check if the correct minimum symbol length is set.
Check to make sure that the baud rate and parity of the scanner
and the communication port match and the program is looking
for RS232 data.
Check that the scanner and the host are configured for the
same interface.
Add some intercharacter delay to the transmitted output by
using the MetroSelect Configuration Guide (
Refer to the user's guide provided with the secondary scanner.
Ensure that the secondary scanner is connected to the MS2122
com port marked "Aux" port.
* The MS2122 must be programmed to enable the auxiliary
port.
The auxiliary input port's data format must match the main
output format of the secondary scanner.
00-02034x) under Scanner Configuration Bar Codes:
MLPN
Solution
00-02407x).
MLPN

Advertisement

Table of Contents
loading