Metrologic Stratos MS2xxx Series Configuration Addendum

Metrologic Stratos MS2xxx Series Configuration Addendum

Metrologic instruments scanner configuration addendum
Table of Contents

Advertisement

Quick Links

METROLOGIC INSTRUMENTS, INC.
MS2xxx Stratos
Series
®
Configuration Addendum

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Stratos MS2xxx Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Metrologic Stratos MS2xxx Series

  • Page 1 METROLOGIC INSTRUMENTS, INC. MS2xxx Stratos Series ® Configuration Addendum...
  • Page 2 Copyright © 2008 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976.
  • Page 3: Table Of Contents

    Scanner Configuration Bar Codes Dual Cable Scanner Configuration Bar Codes Dual Cable Scanner Mode ... 20 Dual Cable Scanner OPOS Mode... 20 Various Dual Cable Scanner Mode ... 21 IBM 3 Generation 46xx ... 22 IBM OEM Full Speed USB ... 22 Single Cable Scanner Protocols for P.O.S.
  • Page 4 Additional Scanner Configuration Bar Codes Horizontal Depth of Field... 53 Vertical Depth of Field... 55 Auxiliary Port Stratos School... 57 Quick Start for a Secondary Metrologic Scanner ... 58 EAS Bar Codes EAS Device Types ... 60 EAS Timeout ... 63 EAS Connection... 68...
  • Page 5 ABLE OF ONTENTS Continuous Mode ... 71 EAS Deactivation ... 72 Sensormatic ScanMax Pro... 75 Scanner Test Bar Codes Supplemental Tests... 77 Display Software Numbers... 77 Contact Information and Office Locations... 78...
  • Page 6: Important Notes - Before You Start

    Be calibrated, sealed and certified by local Weights and Measures authorities after the scale configuration process has been completed. The scanner/scale can not be placed in service until it is sealed and certified by the proper authorities. For further details on calibration procedures for Weights and Measures certification, refer to the Scale Operation: Calibration section of the Stratos Installation and User’s Guide.
  • Page 7: Scale Program Mode

    Always follow all Electro-Static Discharge (ESD) procedures when exposing the internal scanner/scale components. Enter the scale program mode by sliding the switch to the program position. See Figure 2 below for the switch location on the StratosE and StratosH.
  • Page 8 Metrologic recommends using a switched AC outlet. The switch should be located on the operator’s side of the checkout counter in close proximity to the scanner/scale to facilitate calibration and service of the unit. To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950-1.
  • Page 9 Installation and User’s Guide. The certification of the weighing mechanism of the scale version of this scanner is subject to federal, state and local Weights and Measures statutes and regulations and can only be performed by authorized government agencies and/or their duly registered agents.
  • Page 10: Scale/Load Cell Configuration Bar Codes

    CALE Single or Dual Cable Scale Configuration Bar Codes Unit Configuration (Pounds or Kilograms) The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. Scale = Pounds ³...
  • Page 11: Pole Display Configuration

    Set the scale to not use a remote display. All weights are expected on a POS terminal display. A remote display can not be plugged into the Scale RS485 to Display connector on the scanner/scale (see Figure 7) or this feature will not function properly. ODES...
  • Page 12: Scale Settling Filter Configuration

    CALE Single or Dual Cable Scale Configuration Bar Codes Scale Settling Filter Configuration The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. The scale’s filter setting allows the unit to withstand a certain amount of vibration from the checkout counter.
  • Page 13: Single Or Dual Cable Scale Configuration Bar Codes

    CALE Single or Dual Cable Scale Configuration Bar Codes Scale Settling Filter Configuration The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. Scale = Medium Filter ³...
  • Page 14: Scroll Weight Configuration

    CALE Single or Dual Cable Scale Configuration Bar Codes Scroll Weight Configuration The following bar codes can be used to configure a Single or Dual Cable MS2xx0. The MS2xx0 must be in scale program mode to use these bar codes. These bar codes only affect the pole display.
  • Page 15: Dual Cable Scale Configuration Bar Codes

    CALE Dual Cable Scale Configuration Bar Codes Price Computing Configuration The following bar codes are only used when the scale is in Dual Cable mode. The MS2xx0 must be in scale program mode to use these bar codes. * Scale = No Price Computing ³...
  • Page 16: Scale Protocols

    Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 20. The MS2xx0 must be in scale program mode to use these bar codes.
  • Page 17 Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 20. The MS2xx0 must be in scale program mode to use these bar codes.
  • Page 18 Scale Protocols The following bar codes will change scale parameters intended for a Dual Cable environment. To place the scanner in Dual Cable mode, please refer to page 20. The MS2xx0 must be in scale program mode to use these bar codes.
  • Page 19: Scale Com Port Settings (Baud Rate)

    CALE Dual Cable Scale Configuration Bar Codes COM Port Settings (Baud Rate) The following bar codes will change scale parameters intended for a Dual Cable environment. If a Scale Protocol bar code from page 11 or 13 is used, the bar codes below must be scanned after the Scale Protocol bar code in order to be effective.
  • Page 20 CALE Dual Cable Scale Configuration Bar Codes COM Port Settings (Baud Rate) The following bar codes will change scale parameters intended for a Dual Cable environment. If a Scale Protocol bar code from page 11 or 13 is used, the bar codes below must be scanned after the Scale Protocol bar code in order to be effective.
  • Page 21: Dual Cable Scale Configuration Bar Codes

    CALE Dual Cable Scale Configuration Bar Codes COM Port Settings (Data Bits & Parity) The following bar codes will change scale parameters intended for a Dual Cable environment. If a Scale Protocol bar code from page 11 or 13 is used, the bar codes below must be scanned after the Scale Protocol bar code in order to be effective.
  • Page 22 CALE Dual Cable Scale Configuration Bar Codes COM Port Settings (Data Bits & Parity) The following bar codes will change scale parameters intended for a Dual Cable environment. If a Scale Protocol bar code from page 11 or 13 is used, the bar codes below must be scanned after the Scale Protocol bar code in order to be effective.
  • Page 23 CALE Dual Cable Scale Configuration Bar Codes COM Port Settings (Data Bits & Parity) The following bar codes will change scale parameters intended for a Dual Cable environment. If a Scale Protocol bar code from page 11 or 13 is used, the bar codes below must be scanned after the Scale Protocol bar code in order to be effective.
  • Page 24: Single Cable Scale Configuration Bar Codes

    The MS2xx0 must be in scale program mode to use this bar code. If your application requires single cable communication, scan the following bar code to set the scale configuration to the single cable defaults as required by the scanner. Scale = Single Cable Interface ³...
  • Page 25: Scanner Configuration Bar Codes

    • 9600 Baud, 8 Data Bits, 1 Stop Bit, No Parity There are two methods of configuring the scanner to a stand-alone protocol: • Scan the Dual Cable Mode bar code on this page (if a scale is used) • If no scale is required, scan one of the single cable protocols on pages 23 - 32 and then scan the No Scale bar code on page 44.
  • Page 26: Various Dual Cable Scanner Mode

    CANNER ONFIGURATION Dual Cable Scanner Configuration Bar Codes Various Dual Cable Scanner Mode The following bar codes can be used to configure a Dual Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
  • Page 27: Dual Cable Scanner Configuration Bar Codes

    CANNER ONFIGURATION Dual Cable Scanner Configuration Bar Codes IBM 3 Generation 46xx and IBM OEM Full Speed USB The following bar codes can be used to configure a Dual Cable MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode.
  • Page 28: Mss Global

    Communication Port Settings: • 9600 Baud • 7 Data Bits • 1 Stop Bit • Odd Parity Scanner/Scale, Single Cable RS232 MSS Global Retail, Metric Units Communication Port Settings: • 9600 Baud • 7 Data Bits • 1 Stop Bit •...
  • Page 29: Iss45

    The following codes do not require that the MS2xx0 to be in scale program mode. ISS45, English ³ ISS45, Metric ³ ODES Scanner/Scale, Single Cable RS232 ISS45, English Units Communication Port Settings: • 9600 Baud • 7 Data Bits •...
  • Page 30: Opos

    The following codes do not require that the MS2xx0 to be in scale program mode. OPOS, English ³ OPOS, Metric ³ ODES Scanner/Scale Single Cable RS232 OPOS, English Scale Defaults Communication Port Settings: • 9600 Baud • 8 Data Bits •...
  • Page 31: Retailix/Ncr

    The following codes do not require that the MS2xx0 to be in scale program mode. Retailix/NCR English ³ Retailix/NCR Metric ³ ODES Scanner/Scale Single Cable RS232 Retailix/NCR Communication, English Communication Port Settings: • 9600 Baud • 8 Data Bits •...
  • Page 32: Retailix/Opos

    MS2xx0. The following codes do not require that the MS2xx0 to be in scale program mode. Retailix / OPOS Metric ³ ODES Scanner/Scale Single Cable RS232 Retailix / OPOS Communication, Metric Communication Port Settings: • 9600 Baud • 8 Data Bits •...
  • Page 33: It Retail

    The following codes do not require that the MS2xx0 to be in scale program mode. IT Retail, English ³ IT Retail, Metric ³ ODES Scanner/Scale Single Cable RS232 IT Retail, English Communication Port Settings: • 9600 Baud • 7 Data Bits •...
  • Page 34: Ibm Self Checkout System

    The following codes do not require that the MS2xx0 to be in scale program mode. IBM Self Checkout System, English ³ IBM Self Checkout System, Metric ³ ODES Scanner/Scale Single Cable RS232 - IBM Self Checkout System, English Communication Port Settings: • 19200 Baud • 7 Data Bits • 1 Stop Bit •...
  • Page 35: Various Rs232 Single Cable Codes

    The following codes do not require that the MS2xx0 to be in scale program mode. Morrison’s Tec Metric ³ Reliance India Metric ³ ODES Scanner/Scale Single Cable RS232 – Morrison’s with Tec Display, Metric Communication Port Settings: • 9600 Baud • 7 Data Bits •...
  • Page 36: Ibm 3 Rd Generation 46Xx

    IBM 3 Generation 46xx, † English ³ † Terminal Configuration, IBM 4690.OS Terminal Device Group Configuration screen select: #2 Scanner with integrated scale #4 4696 scanner/scale IBM 3 Generation 46xx, † Metric ³ ODES Scanner/Scale Single Cable IBM 46xx English (lbs.)
  • Page 37: Ibm Oem Full Speed Usb

    Full Speed USB, English ³ IBM OEM Full Speed USB, Metric ³ ODES Table Top Scanner/Scale Single Cable, IBM OEM Full Speed USB, 4-Digit Weight Mode, English (lbs.) Table Top Scanner/Scale Single Cable, IBM OEM Full Speed USB, 5-Digit Weight Mode, Metric (kg)
  • Page 38: Additional Pos Data Formatting Full Speed Usb Table Top/Handheld

    ONFIGURATION Additional POS Data Formatting Full Speed USB Table Top/Handheld The following codes do not require that the MS2xx0 to be in scale program mode. Scanner 4B Handheld ³ Scanner 4A Flatbed ³ ODES Full Speed USB interface to 4B00h handheld usage.
  • Page 39 The following codes do not require that the MS2xx0 to be in scale program mode. Scanner/Scale 4A/6E Table Top ³ ODES Full Speed USB interface to the 4A00h/6E00h table top scanner/scale usage. This option is only compatible with Stratos models that have a scale.
  • Page 40: Special Function Ack

    CANNER ONFIGURATION Additional POS Data Formatting Special Function ACK The following codes do not require that the MS2xx0 to be in scale program mode. Enable Special Function ACK Answer ³ * Disable Special Function ACK ³ ODES Answer simple special functions with ACK. * Factory Default Setting...
  • Page 41: Prefix/Suffix

    CANNER ONFIGURATION Additional POS Data Formatting Prefix/Suffix The following codes do not require that the MS2xx0 to be in scale program mode. Use Protocol Prefix/Suffix ³ * Program the Prefix/Suffix Separate ³ ODES Add protocol prefixes and suffixes to the bar code.
  • Page 42: 3X-30 Acknowledge Responses

    No 3x-30 Answer ³ *3x-30 Answer ³ ODES This bar code will inhibit all ‘simple acknowledge’ (3x-30) answers to POS or OPOS commands. The scanner will answer all NCR and OPOS commands that require a 3x-30 acknowledgement. * Factory Default Setting...
  • Page 43: Special Function Command Responses

    CANNER ONFIGURATION Additional POS Data Formatting Special Function Command Responses The following codes do not require that the MS2xx0 to be in scale program mode. Spec Func Ans 3x30 ³ *Spec Func Ans Ack ³ ODES Answer Special Function commands in the 3x-30 format as opposed to the Ack / Nak which is the norm.
  • Page 44 CANNER ONFIGURATION Additional POS Data Formatting Special Function Command Responses The following codes do not require that the MS2xx0 to be in scale program mode. Spec Func 30-30 Status ³ *No Spec Func 30-30 Status ³ ODES Returns Special Function commands in the 30-30 status as opposed to the 33-30 status.
  • Page 45 Answer ³ ODES This bar code will ignore sending a command reject answer to the POS mode. This bar code will send command reject answer to the POS if the command is rejected by the scanner. * Factory Default Setting...
  • Page 46 CANNER ONFIGURATION Additional POS Data Formatting Special Function Command Responses The following codes do not require that the MS2xx0 to be in scale program mode. No Spec Func Answer ³ *Spec Func Answer ³ ODES This bar code will ignore sending a special function response answer in POS mode.
  • Page 47: Bcc In Pos Communications

    ³ *Add BCC in messages ³ ODES This bar code will tell the scanner to NOT expect or transmit the Block Check Character in all message transmissions. The scanner will expect and answer all messages with the Block Check Character included.
  • Page 48: Scale Status Bytes

    Enable 3 Scale Status Bytes ³ Disable 3 Scale Status Bytes ³ ODES Required for applications where the host system display is the primary scale display and there is no remote pole display connected directly to the scanner/scale unit.
  • Page 49: Scale Options

    CANNER ONFIGURATION Additional POS Data Formatting Scale Options The following codes do not require that the MS2xx0 to be in scale program mode. 5-Digit Weight ³ No Scale ³ ODES Sets the English Mode weight to 5-digits, as in xx.yyy pounds. In order to work properly, this bar code must be scanned AFTER scanning one of the English configuration bar codes found on...
  • Page 50: Configuration Bar Codes

    When no remote display is installed, scan the No Remote Display bar code AFTER scanning one of the configuration bar codes found on pages 23 - 32 to remove the scale’s display from the scanner memory. Add remote display to the scanner’s memory.
  • Page 51: Stratosstats

    CANNER ONFIGURATION Additional POS Data Formatting StratosSTATS The following codes do not require that the MS2xx0 to be in scale program mode. Activate StratosSTATS ³ *StratosSTATS Off ³ ODES This bar code sets: • StratosSTATS bar code data formatting active. •...
  • Page 52 CANNER ONFIGURATION Additional POS Data Formatting StratosSTATS The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a Metrologic Representative. Dual Stats Xmit ³ *No Dual Stats Xmit ³...
  • Page 53 CANNER ONFIGURATION Additional POS Data Formatting StratosSTATS The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a Metrologic Representative. Dual Xmit Carriage Return ³ *No Dual Xmit Carriage Return ³...
  • Page 54: Additional Pos Related Functions Scanner Beep On Weight Sent

    ³ *Disable Beep on Weight ³ ODES Request scanner beep when a successful weight is sent. This code should only be used for ‘weight on demand’ applications. If used with periodic weight request applications, the beeper will be continuously active (ON).
  • Page 55: Restrict In-Store Codes

    CANNER ONFIGURATION Additional POS Related Functions Restrict In-Store Codes The following codes do not require that the MS2xx0 to be in scale program mode. Restrict In-Store Codes ³ *No Restrict In-Store Codes ³ ODES This bar code places tighter restrictions on in-store codes.
  • Page 56: Scale Shadow Mode

    CANNER ONFIGURATION Additional POS Related Functions Scale Shadow Mode The following codes do not require that the MS2xx0 to be in scale program mode. Scale Shadow Mode ³ *No Scale Shadow Mode ³ ODES This bar code sets the scale to the highest priority to allow for frequent scale - POS commands.
  • Page 57: Scanner Razz On Not-On-File

    CANNER ONFIGURATION Additional POS Related Functions Scanner Razz on Not-On-File The following codes do not require that the MS2xx0 to be in scale program mode. Razz on Not-On-File ³ *Beep on Not-On-File ³ ODES This bar code changes the audible to a razz signal when a Not-On-File command is received.
  • Page 58: Additional Scanner Configuration Bar Codes Horizontal Depth Of Field

    CANNER ONFIGURATION Additional Scanner Configuration Bar Codes Horizontal Depth of Field The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a Metrologic Representative. *Horizontal High DOF ³...
  • Page 59 CANNER ONFIGURATION Additional Scanner Configuration Bar Codes Horizontal Depth of Field The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a Metrologic Representative. Horizontal Close DOF ³...
  • Page 60: Vertical Depth Of Field

    CANNER ONFIGURATION Additional Scanner Configuration Bar Codes Vertical Depth of Field The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a Metrologic Representative. *Vertical High DOF ³...
  • Page 61 CANNER ONFIGURATION Additional Scanner Configuration Bar Codes Vertical Depth of Field The following codes do not require that the MS2xx0 to be in scale program mode. Do not scan these bar codes unless instructed by a Metrologic Representative. Vertical Close DOF ³...
  • Page 62: Auxiliary Port Stratosschool

    The Auxiliary port may be used to download or clear data to StratosSCHOOL™. The two commands that can be used are Upload Scanner Data and Clear Scanner Data within the Serial Program Interface box on the StratosSCHOOL™ screen. Auxiliary Program Cable...
  • Page 63: Scanner Configuration Bar Codes

    The auxiliary input port’s data format must match the main output format of the secondary scanner Configure the secondary scanner to match the auxiliary port’s data format. Use the Secondary Scanner to scan the following bar codes in the order shown. Enter Configuration Mode ³...
  • Page 64 CANNER ONFIGURATION Auxiliary Port Quick Start for a Secondary Metrologic Scanner Configuration sequence continued from previous page. Set Stratos Format ³ Disable Secondary Scanner Beeper ³ Enable Communication Time Out ³ Disable CR Suffix ³ Disable LF Suffix ³ Exit Configuration Mode ³...
  • Page 65: Eas Bar Codes

    CANNER ONFIGURATION EAS Bar Codes EAS Device Types The following codes do not require that the MS2xx0 to be in scale program mode. *No EAS Device ³ EAS Device Type 1 ³ ODES No EAS device is connected. * Factory Default Setting...
  • Page 66 CANNER ONFIGURATION EAS Bar Codes EAS Device Types The following codes do not require that the MS2xx0 to be in scale program mode. EAS Device Type 2 ³ EAS Device Type 3 ³ ODES...
  • Page 67 CANNER ONFIGURATION EAS Bar Codes EAS Device Types The following codes do not require that the MS2xx0 to be in scale program mode. EAS Device Type 4 ³ ODES...
  • Page 68: Eas Timeout

    CANNER ONFIGURATION EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode. *EAS = 0 seconds ³ EAS = 1 second ³ 8 4 6 0 0 1 0 0 ODES * Factory Default Setting...
  • Page 69 CANNER ONFIGURATION EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode. EAS = 2 seconds ³ 8 4 6 0 0 2 0 0 EAS = 3 seconds ³ 8 4 6 0 0 3 0 0 ODES...
  • Page 70 CANNER ONFIGURATION EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode. EAS = 4 seconds ³ 8 4 6 0 0 4 0 0 EAS = 5 seconds ³ 8 4 6 0 0 5 0 0 ODES...
  • Page 71 CANNER ONFIGURATION EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode. EAS = 7 seconds ³ 8 4 6 0 0 7 0 0 EAS = 10 seconds ³ 8 4 6 0 1 0 0 0 ODES...
  • Page 72 CANNER ONFIGURATION EAS Bar Codes EAS Timeout The following codes do not require that the MS2xx0 to be in scale program mode. EAS = 15 seconds ³ 8 4 6 0 1 5 0 0 EAS = 20 seconds ³ 8 4 6 0 2 0 0 0 ODES...
  • Page 73: Eas Connection

    EAS Digital Host Port ³ ODES The EAS signals use the RTS and CTS line of the Auxiliary RS232 In connector. * Factory Default Setting The EAS signals use the RTS and CTS lines of the scanner RS232 to Host connector.
  • Page 74 Tx Out and Rx In lines of the scanner to Aux RS232 In connector. There is no EAS RS232 signal (Tx Out and Rx In) used on the scanner Aux RS232 In connector. * Factory Default Setting...
  • Page 75 Tx Out and Rx In lines of the scanner to Host RS232 In connector. There is no EAS RS232 signal (Tx Out and Rx In) used on the scanner to Host RS232 In connector. * Factory Default Setting...
  • Page 76: Continuous Mode

    EAS Continuous Mode ³ *EAS Interlock Mode ³ ODES When in continuous mode and the scanner is enabled, the EAS will always be online to deactivate an EAS tag. This bar code establishes EAS is used in the Interlocked mode.
  • Page 77: Eas Deactivation

    Deactivation ³ *No Blink LED on Deactivation ³ ODES The scanner will blink the scan LED upon receipt of an EAS deactivate acknowledge signal. Do not blink the scan LED upon receipt of an EAS deactivate acknowledge signal. * Factory Default Setting...
  • Page 78 Fast Beep on Deactivation ³ *No Beep on Deactivation ³ ODES Fast beep the scanner’s beeper receipt of an EAS deactivate acknowledge signal. Do not fast beep the scanner’s beeper receipt of an EAS deactivate acknowledge signal. * Factory Default Setting...
  • Page 79 CANNER ONFIGURATION EAS Bar Codes EAS Deactivation The following codes do not require that the MS2xx0 to be in scale program mode. Volume Switch = Manual ³ *Volume Switch = Normal ³ ODES The volume switch is used for manual EAS deactivation.
  • Page 80: Sensormatic Scanmax Pro

    EAS Bar Codes Sensormatic ScanMax Pro The following codes do not require that the MS2xx0 to be in scale program mode. The RS232 EAS cable must be connected to one of the RS232 scanner ports. EAS Function #3 ³ EAS Function #2 ³...
  • Page 81 EAS Bar Codes Sensormatic ScanMax Pro The following codes do not require that the MS2xx0 to be in scale program mode. The RS232 EAS cable must be connected to one of the RS232 scanner ports. EAS Function #1 ³ ScanMax RS232 Defaults ³...
  • Page 82: Scanner Test Bar Codes

    The forth and fifth digits. x = Blank / No Digit Displayed After the last sets of digits are displayed, the scanner resumes scanning operation. If the current interface does not use an I/O processor, the software number may appear ‘ 0 00 00’. This capability exists in software 15269 and later.
  • Page 84 OTES...
  • Page 85 OTES...
  • Page 88 May 2008 Printed in the USA 0 0 - 0 2 0 3 4 E...

This manual is also suitable for:

Stratos ms2 series

Table of Contents