Safety Rules
Safety & Handling Regulations
1. Approximately 10 minute pre-run time is required before any adjustments are performed.
2. Do not adjust for higher or lower voltage ( Refer to Voltage Sticker inside the Panel ) than is specified for the product.
3. Be cautious of electric shock from the PDP module since the PDP module uses high voltage, it is recommended that you
should not touch the Power Supply or Drive circuits for at least one minute because of residual current stored.
4. C-MOS circuits are used extensively for processing the Drive Signals and should be protected from static electricity.
5. The PDP Module must be carried by two people.
6. Be careful of short circuits when measuring voltages.
7. Be cautious of screws and other metal objects to prevent a short in the circuitry.
Checking Point before Requesting MODULE Repair
1. Check the appearance of Panel and boards.
2. Check the model label. Verify model names and board model matches.
3. Check details of defective condition and history.
Ex) COF long 2-1 fail, address 1 line open, Y b/d trouble, Mal-discharge on screen.