Disposal; Extension And Conversion; Troubleshooting - Bosch Rexroth IMdev Manual

Table of Contents

Advertisement

26/84
Bosch Rexroth AG

12 Disposal

12
Disposal
Environmental protection
Careless disposal of the IMdev interface
module could lead to pollution of the
environment.
Therefore dispose of the device in
accordance with the currently applicable
regulations in your country.
You can also send the device to Bosch
Rexroth for disposal.
13
Extension and
conversion
Do not convert the IMdev interface module.
IMdev | 3 609 929 B41/2008-09
14

Troubleshooting

Malfunctions and information on errors are
displayed in the tightening system, e.g. in the
BS350.
The NS LED indicates the network status.
Table 6 NS LED malfunction table
LED
Meaning
display
Red
Error in the interface module, critical
connection error, device has
detected a network error (double
MAC ID or bus off)
Flashing
Communication has failed, severe
red (1 Hz)
communication error
The MS LED indicates the module status.
Table 7 MS LED malfunction table
LED
Meaning
display
Flashing
Missing or incomplete
green
configuration
(1 Hz)
Red
The IMdev interface module can
only be made ready for operation
through measures performed by
the user.
Flashing
Fault has been self-acknowledged
red (1 Hz)
after the IMdev interface module
has remedied it.
If you should not be able to remedy an
occurring defect, please contact one of the
addresses that you can find under
www.boschrexroth.com or in the address
directory in chapter "16 Service and sales"
on page 28.