Maintenance Schedule

After Each Load
Remove debris from the wash drum including paper clips, coins,
and other hard items.
When not in use, leave the washer door open to allow the
washer to air out and prolong gasket life.
Daily Maintenance
Clean water, detergent, and other stains off of the washer with
a soft cloth dampened with a mild detergent solution.
Dry with a soft cloth. Do not use abrasives.
Clean detergent residue and other contamination off the door
seal with a soft cloth dampened only with a mild detergent
solution. Do not use solvents or acids. Do not lubricate seal
with oil or grease.
Remove residue from the detergent hoppers with a plastic
scraper. Wipe the hoppers with a soft cloth dampened with
water.
Check water inlets for leaks. Correct as necessary.
Check drain valve for leakage during a wash cycle (the valve
is in open position when there is no electricity to it).
Maintenance Every 200 Working Hours or Every Month
Make sure external liquid soap supply system is not leaking.
Check all hose joints, screw joints and all connections in the system.
Maintenance Every 500 Working Hours or 3 Months
Observe the washer from the back for one wash cycle.
Be sure that water does not leak out of the drain during
the wash part of the cycle and that it drains freely at the
beginning of extraction. Clean the drain if either of these
symptoms are observed.
1. Turn off power to washer at the circuit breaker or fuse box.
2. Check the tightness of the bolts securing the rear panel
of the washer.
3. Check the belt tightness or for belt damage. See "Belt
Inspection, Adjustment, and Replacement. "
16

WASHER MAINTENANCE

4. Check mounting bolt tightness. Retighten if necessary
(fixed installation only).
5. Inspect all hoses and connections inside the washer for
leaks and correct as necessary.
6. Wipe off any stains with a soft cloth dampened with water
or a mild detergent solution. Be sure that control components
are not exposed to dust and moisture during cleaning.
7. Put covers back on and check that all bolts are properly torqued.
8. Turn on power at circuit breaker or fuse box.
Maintenance Every 1000 Working Hours or 6 Months
Turn off hot and cold water to the washer at the valves.
Clean water filters.
Clean and remove dirt and dust from:
– the inverter cooling fin
– the motor cooling fins
– the inverter internal fan (if present)
– the external fan (if present)
– the external air relieves.
Make sure the fan in the inverter cool fins (if present)
is functioning.
Make sure the external fan (if present) is functioning.
Maintenance Every 2000 Working Hours or 12 Months
Soft-Mount Models: Adjust and perform functional test on
vibration switch (see "Vibration Switch Adjustment and Function
Testing").