On the control panel, set the Function Select switch
to Console Link Test.
Function Select
Remote CNSL Function
General
Disconnect
Start
o
D'
D
Activate the Function Start switch.
Read the progression and results of the Console Link Test on the
hexadecimal display of the control panel.
~---------------------------------------------)
Approximately one minute after you have activated
the Function Start switch, 44E is displayed.
If
4 4 E remains more than 20 seconds
l
it indicates: TEST OK
_----------J
~
• Remove all wrap plugs from console sockets or
cables. Ignore the hexadecimal codes that may
be displayed when the wrap plugs are removed.
• Reconnect the console cables to the consoles.
• Set the Function Select switch to MOSS IML.
• Activate the Function Start switch.