Technical Specifications
General
Order nos.
Dimensions (w x h x d)
Weight
Supply voltage (U
)
N
Line voltage frequency
Brief voltage interruption acc. to Namur
max. power consumption
max. current output
Noise emission
Enclosure
Safety
Protection class
Safety specifications
Electromagnetic Compatibility (EMC)
Emitted interference
Noise immunity:
Mains borne disturbance variables on
supply lines
Noise immunity on signal lines
Noise immunity to discharges of static
electricity
Immunity to RF interference
Magnetic field
B-2
See order documentation
430.4x177.4x44.4 (w x h x d in mm)
For more details refer to chapter 3.2
min. 16 kg, max. 23 kg
120 V AC to 240 V AC (90 ... 264 V AC)
50 - 60 Hz
61 ms at 0.85 U
N
(max. 10 times per hour; min. recovery time 1 s)
460 W
+3,3V/18A
+5V/20A
(in total 135W)
+12V/18A
–12V/1A
+5Vaux/2A
< 45 dB(A) to DIN 45635
IP 30 front, IP 20 at the rear
Protection class I acc. to IEC 60536
IEC 60950 acc. to DIN VDE 0805, EN 60950, UL 60950,
cULus
EN 55022 Class B, FCC Class A, EN 61000-3-2 Class D and
EN 61000-3-3
± 2 kV
(to IEC 61000-4-4; Burst)
± 1 kV
(to IEC 61000-4-5; Surge symm)
± 2 kV
(to IEC 61000-4-5; Surge unsymm)
± 1 kV
(to IEC 61000-4-4; Burst; length < 10m)
± 1 kV
(to IEC 61000-4-5; Surge symm; length > 30m)
± 2 kV
(to IEC 61000-4-5:1995; Surge unsymm;
length > 30 m)
± 4 kV contact discharge
± 8 kV air discharge
10 V/m 80-1000 MHz, 80% AM (to IEC 61000-4-3)
10 V/m 900 MHz and 1.89 GHz, 50% ED
(to IEC 61000-4-3)
10 V 9KHz- 80MHz
30 A/m 50/60Hz
(to IEC 61000-4-2)
(to IEC 61000-4-2)
(to IEC 61000-4-6)
(to IEC 61000-4-8)